Automatic Traffic Control

37

Automatic Traffic Control

Use the Traffic > Congestion Control > Auto Traffic Control pages to configure bounding thresholds
for broadcast and multicast storms which can automatically trigger rate limits or shut down a port.

CLI References

“Automatic Traffic Control Commands”

on page 313

Command Usage

ATC includes storm control for broadcast or multicast traffic. The control response for either of
these traffic types is the same, as shown in the following diagrams.

FIGURE 133

Storm Control by Limiting the Traffic Rate

The key elements of this diagram are described below:

Alarm Fire Threshold – The highest acceptable traffic rate. When ingress traffic exceeds the
threshold, ATC sends a Storm Alarm Fire Trap and logs it.

When traffic exceeds the alarm fire threshold and the apply timer expires, a traffic control
response is applied, and a Traffic Control Apply Trap is sent and logged.

Alarm Clear Threshold – The lower threshold beneath which a control response can be
automatically terminated after the release timer expires. When ingress traffic falls below this
threshold, ATC sends a Storm Alarm Clear Trap and logs it.

When traffic falls below the alarm clear threshold after the release timer expires, traffic control
(for rate limiting) will be stopped and a Traffic Control Release Trap sent and logged. Note that
if the control action has shut down a port, it can only be manually re-enabled using Manual
Control Release (see

page 786

).

The traffic control response of rate limiting can be released automatically or manually. The
control response of shutting down a port can only be released manually.

Storm Alarm

Fire TRAP

Alarm Fire
Threshold
(1~255kpps)

AlarmClear
Threshold
(1~255kpps)

Traffic

[kpps]

Time

Traffic without storm control

Traffic with storm control

Apply Timer
expired

(0~300sec)

Auto Storm Control

Release Timer
expired
(0~300sec)

Storm Alarm

Fire TRAP

StromAlarm

ClearTRAP

TrafficControl
Apply Trap

StromAlarm

ClearTRAP

TrafficControl
Release Trap

Storm Alarm

Fire TRAP

Alarm Fire
Threshold
(1~255kpps)

AlarmClear
Threshold
(1~255kpps)

Traffic

[kpps]

Time

Traffic without storm control

Traffic with storm control

Apply Timer
expired

(0~300sec)

Auto Storm Control

Release Timer
expired
(0~300sec)

Storm Alarm

Fire TRAP

StromAlarm

ClearTRAP

TrafficControl
Apply Trap

StromAlarm

ClearTRAP

TrafficControl
Release Trap

Advertising