ERPS Commands

19

Related Commands

erps (360)

guard-timer

This command sets the guard timer to prevent ring nodes from receiving outdated R-APS
messages. Use the no form to restore the default setting.

Syntax

guard-timer milliseconds

milliseconds - The guard timer is used to prevent ring nodes from receiving outdated R-APS
messages. During the duration of the guard timer, all received R-APS messages are
ignored by the ring protection control process, giving time for old messages still circulating
on the ring to expire. (Range: 10-2000 milliseconds, in steps of 10 milliseconds)

Default Setting

500 milliseconds

Command Mode

ERPS Configuration

Command Usage

The guard timer duration should be greater than the maximum expected forwarding delay for an
R-APS message to pass around the ring. A side-effect of the guard timer is that during its duration,
a node will be unaware of new or existing ring requests transmitted from other nodes.

Example

Console(config-erps)#guard-timer 300

Console(config-erps)#

holdoff-timer

This command sets the timer to filter out intermittent link faults. Use the no form to restore the
default setting.

Syntax

holdoff-timer milliseconds

milliseconds - The hold-off timer is used to filter out intermittent link faults. Faults will only
be reported to the ring protection mechanism if this timer expires. (Range: 0-10000
milliseconds, in steps of 100 milliseconds)

Default Setting

0 milliseconds

Command Mode

ERPS Configuration