No rspan session, Show rspan, No rspan session show rspan – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual

Page 358

Advertising
background image

308

Brocade 6910 Ethernet Access Switch Configuration Guide

53-1002581-01

RSPAN Mirroring Commands

14

Only destination and uplink ports will be assigned by the switch as members of this VLAN.
Ports cannot be manually assigned to an RSPAN VLAN with the

switchport allowed vlan

command. Nor can GVRP dynamically add port members to an RSPAN VLAN. Also, note that
the

show vlan

command will not display any members for an RSPAN VLAN, but will only show

configured RSPAN VLAN identifiers.

Example

The following example enables RSPAN on VLAN 2, specifies this device as an RSPAN destination
switch, and the uplink interface as port 3:

Console(config)#rspan session 1 remote vlan 2 destination uplink ethernet 1/3

Console(config)#

no rspan session

Use this command to delete a configured RSPAN session.

Syntax

no rspan session session-id

session-id – A number identifying this RSPAN session. (Range: 1)

Only two mirror sessions are allowed, including both local and remote mirroring. If local
mirroring is enabled with the

port monitor

command, then there is only one session

available for RSPAN.

Command Mode

Global Configuration

Command Usage

The no rspan session command must be used to disable an RSPAN VLAN before it can be deleted
from the VLAN database (see the

vlan

command).

Example

Console(config)#no rspan session 1

Console(config)#

show rspan

Use this command to displays the configuration settings for an RSPAN session.

Syntax

show rspan session [session-id]

session-id – A number identifying this RSPAN session. (Range: 1)

Only two mirror sessions are allowed, including both local and remote mirroring. If local
mirroring is enabled with the

port monitor

command, then there is only one session

available for RSPAN.

Command Mode

Privileged Exec

Advertising