H3-01: terminal a1 signal level selection, H3-02: terminal a1 function selection, Selects the input signal level for analog input a1 – Yaskawa CIMR-AU 200V Drives User Manual

Page 178: 6 basic drive setup adjustments

Advertising
background image

L4-02

L4-02

Frequency
reference

Speed agree 1

ON

OFF

Output Frequency

or Motor Speed

Figure 4.27 Speed Agree 1 Time Chart

Setting 3: User-Set Speed Agree 1 (f

ref

/f

set

Agree 1)

Closes when the actual output frequency or motor speed (CLV, CLV/PM) and the frequency reference are within the speed

agree width (L4-02) of the programmed speed agree level (L4-01).

Status

Description

Open

Output frequency or motor speed and frequency reference are not both within the range of L4-01 ±L4-02.

Closed

Output frequency or motor speed and the frequency reference are both within the range of L4-01 ±L4-02.

Note:

Frequency detection works in forward and reverse. The value of L4-01 is used as the detection level for both directions.

Frequency reference

Frequency reference

+

L4-02

Frequency reference – L4-02

L4-01

L4-01

+

L4-02

L4-01 – L4-02

Frequency reference

Frequency reference

+

L4-02

Frequency reference – L4-02

–L4-01

–L4-01

+

L4-02

–L4-01 – L4-02

During

Forward

During Reverse

Output frequency

0 Hz

OFF

OFF

OFF

ON

ON

ON

ON

Output frequency

User Set
Speed Agree 1

Figure 4.28 User Set Speed Agree 1 Time Chart

n

H3-01: Terminal A1 Signal Level Selection

Selects the input signal level for analog input A1.

No.

Name

Setting Range

Default

H3-01

Terminal A1 Signal Level Selection

0 to 1

0

Setting 0: 0 to 10 Vdc

The input level is 0 to 10 Vdc. The minimum input level is limited to 0%, so that a negative input signal due to gain and bias

settings will be read as 0%.

Setting 1: -10 to 10 Vdc

The input level is -10 to 10 Vdc. If the resulting voltage is negative after being adjusted by gain and bias settings, then the

motor will rotate in reverse.

n

H3-02: Terminal A1 Function Selection

Selects the input signal level for analog input A1.

No.

Name

Setting Range

Default

H3-02

Terminal A1 Function Selection

0 to 32

0

4.6 Basic Drive Setup Adjustments

178

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide