6.1 Inspection

Power electronics have limited life and may exhibit changes in characteristics or performance deterioration after years of use

under normal conditions. To help avoid such problems, it is important to perform preventive maintenance and periodic

inspection on the drive.
Drives contain a variety of power electronics such as power transistors, semiconductors, capacitors, resistors, fans, and relays.

The electronics in the drive serve a critical role in maintaining proper motor control.
Follow the inspection lists provided in this chapter as a part of a regular maintenance program.
Note: The drive will require more frequent inspection if it is placed in harsh environments, such as:
• High ambient temperatures
• Frequent starting and stopping
• Fluctuations in the AC supply or load
• Excessive vibrations or shock loading
• Dust, metal dust, salt, sulfuric acid, chlorine atmospheres
• Poor storage conditions.
Perform the first equipment inspection one to two years after installation.

u

Recommended Daily Inspection

Table 6.1

outlines the recommended daily inspection for Yaskawa drives. Check the following items on a daily basis to avoid

premature deterioration in performance or product failure. Copy this checklist and mark the “Checked” column after each

inspection.

Table 6.1 General Recommended Daily Inspection Checklist

Inspection Category

Inspection Points

Corrective Action

Checked

Motor

Inspect for abnormal oscillation or noise coming from

the motor.

• Check the load coupling.
• Measure motor vibration.
• Tighten all loose components.

Cooling

Inspect for abnormal heat generated from the drive or

motor and visible discoloration.

Check for the following:
• Excessive load.
• Loose connections.
• Dirty heatsink or motor.
• Ambient temperature.

Inspect drive cooling fan and circulation fan operation.

Check for the following:
• Clogged or dirty fan.
• Correct Fan operation parameter setting.

Environment

Verify the drive environment complies with the

specifications listed in

Installation Environment

on

page

28

.

Eliminate the source of contaminants or correct poor

environment.

Load

The drive output current should not be higher than the

motor or drive rating for an extended period of time.

Check for the following:
• Excessive load.
• Correct motor parameter settings.

Power Supply Voltage

Check main power supply and control voltages.

• Correct the voltage or power supply to within

nameplate specifications.

• Verify all main circuit phases.

6.1 Inspection

228

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide

Advertising