Three-Phase 400 V Class Drive Models 4A0038 to 4A0165

Table A.6 Power Ratings Continued (Three-Phase 400 V Class)

Item

Specification

Drive Models

4A0038 4A0044 4A0058 4A0072

4A0088

4A0103 4A0139 4A0165

Maximum Applicable Motor

Capacity (HP)

<1>

ND Rating

25

30

40

50

60

75

100

125

HD Rating

20

25-30

25-30

40

50-60

50-60

75

100

Input

Input Current (A)

<2>

ND Rating

44

52

58

71

86

105

142

170

HD Rating

39

44

43

58

71

86

105

142

Rated Voltage

Rated Frequency

Three-phase: 380 to 480 Vac 50/60 Hz/510 to 680 Vdc

<3>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency Fluctuation

±5%

Input Power (kVA)

ND Rating

40

48

53

65

79

96

130

155

HD Rating

36

40

39

53

65

79

96

130

Output

Rated Output Capacity

(kVA)

<4>

ND Rating

<5>

29

34

44

55

67

78

106

126

HD Rating

24

30

34

46

57

69

85

<7>

114

<7>

Rated Output Current

(A)

ND Rating

<5>

38

44

58

72

88

103

139

165

HD Rating

31

<6>

39

<6>

45

<6>

60

<6>

75

<6>

91

<6>

112

<7>

150

<7>

Overload Tolerance

ND Rating: 120% of rated output current for 60 s

HD Rating: 150% of rated output current for 60 s

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User adjustable between 1 and 15 kHz

User adjustable

between 1 and

10 kHz

Maximum Output Voltage (V)

Three-phase: 380 to 480 Vac (proportional to input voltage)

Maximum Output Frequency (Hz)

400 Hz (user-adjustable)

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions,

and power supply impedance.

<3> DC input is not available for UL standards.
<4> Rated motor capacity is calculated with a rated output voltage of 440 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased to 8 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<7> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.