A.2 power ratings – Yaskawa CIMR-AU 200V Drives User Manual

Page 254

Advertising
background image

u

Three-Phase 400 V Class Drive Models 4A0208 to 4A1200

Table A.7 Power Ratings Continued (Three-Phase 400 V Class)

Item

Specification

Drive Models

4A0208 4A0250 4A0296 4A0362 4A0414 4A0515 4A0675 4A0930 4A1200

Maximum Applicable Motor

Capacity (HP)

<1>

ND Rating

150

200

250

300

350

400-450 500-550

750

1000

HD Rating

125-150

150

200

250

300

350

400-450-

500

650

900

Input

Input Current (A)

<2>

ND Rating

207

248

300

346

410

465

657

922

1158

HD Rating

170

207

248

300

346

410

584

830

1031

Rated Voltage

Rated Frequency

Three-phase: 380 to 480 Vac 50/60 Hz/510 to 680 Vdc

<3>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency Fluctuation

±5%

Input Power (kVA)

ND Rating

189

227

274

316

375

425

601

843

1059

HD Rating

155

189

227

274

316

375

534

759

943

Output

Rated Output Capacity

(kVA)

<4>

ND Rating

<5>

189

227

274

316

375

425

601

843

1059

HD Rating

137

<6>

165

<6>

198

<6>

232

<6>

282

<6>

343

<5>

461

<5>

617

<5>

831

<5>

Rated Output Current

(A)

ND Rating

<5>

208

250

296

362

414

515

675

930

1200

HD Rating

180

<6>

216

<6>

260

<6>

304

<6>

370

<7>

450

<5>

605

<5>

810

<5>

1090

<5>

Overload Tolerance

ND Rating: 120% of rated output current for 60 s

HD Rating: 150% of rated output current for 60 s

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User-adjustable between 1 and 10 kHz

User-adjustable between 1 and 5 kHz

Maximum Output Voltage (V)

Three-phase: 380 to 480 Vac (proportional to input voltage)

0.95 ×

[input voltage]

Maximum Output Frequency (Hz)

400 Hz (user-adjustable)

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions,

and power supply impedance.

<3> DC input is not available for UL standards.
<4> Rated motor capacity is calculated with a rated output voltage of 440 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<7> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.

A.2 Power Ratings

254

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide