Yaskawa CIMR-AU 200V Drives User Manual

Page 278

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

C5-04

(021E) ASR Integral Time 2

ASR I Time 2

Sets the integral time 2 of the speed control loop (ASR).

Default:

<1>

Min.: 0.000 s

Max.: 10.000 s

C5-05

(021F) ASR Limit

ASR Limit

Sets the upper limit for the speed control loop (ASR) as a

percentage of the maximum output frequency (E1-04).

Default: 5.0%

Min.: 0.0

Max.: 20.0

C5-06

(0220)

ASR Primary Delay

Time Constant

ASR Delay Time

Sets the filter time constant for the time from the speed loop to

the torque command output.

Default:

<1>

Min.: 0.000 s

Max.: 0.500 s

C5-07

(0221)

ASR Gain Switching

Frequency

ASR Gain Switch

Sets the frequency for switching between proportional gain 1,

2 and integral time 1, 2.

Default: 0.0 Hz

Min.: 0.0

Max.: 400.0

C5-08

(0222)

ASR Integral Limit

ASR I Limit

Sets the ASR integral upper limit as a percentage of rated load

torque.

Default: 400%

Min.: 0

Max.: 400

C5-12

(0386)

Integral Operation

during Accel/Decel

Acc/Dec I Sel

0: Disabled. Integral functions are enabled only during constant

speed.

1: Enabled. Integral functions are always enabled, during accel/

decel and during constant speed.

Default: 0

Range: 0, 1

C5-17

(0276)

Motor Inertia

Motor Inertia

Sets the motor inertia. This value is automatically set during

ASR or Inertia Auto-Tuning.

Default:

<3> <4>

Min.: 0.0001

kgm

2

Max.: 600.00

kgm

2

C5-18

(0277)

Load Inertia Ratio

Load Inertia

Sets the ratio between the motor and load inertia. This value is

automatically set during ASR or Inertia Auto-Tuning.

Default: 1.0

Min.: 0.0

Max.: 6000.0

C5-21

(0356)

Motor 2 ASR

Proportional Gain 1

ASR P Gain1 Mtr2

Sets the proportional gain of the speed control loop (ASR) for

motor 2.

Default:

<5>

Min.: 0.00
Max.: 300.00

<2>

C5-22

(0357)

Motor 2 ASR Integral

Time 1

ASR I Time1 Mtr2

Sets the integral time of the speed control loop (ASR) for motor

2.

Default:

<5>

Min.: 0.000 s

Max.: 10.000 s

C5-23

(0358)

Motor 2 ASR

Proportional Gain 2

ASR P Gain2 Mtr2

Sets the speed control gain 2 of the speed control loop (ASR)

for motor 2.

Default:

<5>

Min.: 0.00
Max.: 300.00

<2>

C5-24

(0359)

Motor 2 ASR Integral

Time 2

ASR I Time2 Mtr2

Sets the integral time 2 of the speed control loop (ASR) for

motor 2.

Default:

<5>

Min.: 0.000 s

Max.: 10.000 s

C5-25

(035A) Motor 2 ASR Limit

ASR Limit Mtr2

Sets the upper limit for the speed control loop (ASR) for motor

2 as a percentage of the maximum output frequency (E3-04).

Default: 5.0%

Min.: 0.0

Max.: 20.0

C5-26

(035B)

Motor 2 ASR Primary

Delay Time Constant

ASR Dly Time 2

Sets the filter time constant for the time from the speed loop to

the torque command output used for motor 2.

Default:

<5>

Min.: 0.000 s

Max.: 0.500 s

C5-27

(035C)

Motor 2 ASR Gain

Switching Frequency

ASRGainSwitch2

Sets the frequency for motor 2 used to switch between

proportional gain 1 and 2, and between the integral time 1 and

2.

Default: 0.0 Hz

Min.: 0.0

Max.: 400.0

C5-28

(035D)

Motor 2 ASR Integral

Limit

ASR I limit 2

Sets the ASR integral upper limit for motor 2 as a percentage

of rated load torque.

Default: 400%

Min.: 0

Max.: 400

C5-32

(0361)

Integral Operation

during Accel/Decel for

Motor 2

Acc/Dec I Sel 2

0: Disabled

1: Enabled

0: Disabled. Integral functions for motor 2 are enabled only

during constant speed.

1: Enabled. Integral functions are always enabled for motor 2,

during accel/decel and during constant speed.

Default: 0

Range: 0, 1

C5-37

(0278)

Motor 2 Inertia

Motor Inertia 2

Sets the inertia of motor 2 alone without the load. This value

is automatically set during ASR or Inertia Auto-Tuning.

Default:

<3> <4>

Min.: 0.0001

kgm

2

Max.: 600.00

kgm

2

B.3 C: Tuning