Yaskawa CIMR-AU 200V Drives User Manual

Page 342

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Analog

Output Level

Unit

U6-03

(0054) ASR Input

ASR Input

Displays the input and output values when using ASR control. 10 V: Max

frequency

(-10 to +10 V)

0.01%

U6-04

(0055) ASR Output

ASR Output

10 V: Motor

secondary rated

current

(-10 to +10 V)

U6-05

(0059)

Output Voltage

Reference (Vq)

Voltage Ref (Vq)

Output voltage reference (Vq) for the q-Axis.

10 V: 200 Vrms
(-10 to +10 V)

<1>

0.1 Vac

U6-06

(005A)

Output Voltage

Reference (Vd)

Voltage Ref (Vd)

Output voltage reference (Vd) for the d-Axis.

10 V: 200 Vrms
(-10 to +10 V)

<1>

0.1 Vac

U6-07

(005F) q-Axis ACR Output

ACR(q) Output

Displays the output value for current control relative to motor

secondary current (q-Axis).

10 V: 200 Vrms
(-10 to +10 V)

<1>

0.1%

U6-08

(0060) d-Axis ACR Output

ACR(d) Output

Displays the output value for current control relative to motor

secondary current (d-Axis).

110 V: 200 Vrms
(-10 to +10 V)

<1>

0.1%

U6-09

(07C0)

Advance Phase

Compensation (Δθ)

d-q Axis Comp

Displays the degree of forward phase correction after calculating

the deviation of Δθcmp.

10 V: 180 deg

-10 V: -180 deg

(-10 to +10 V)

0.1 deg

U6-10

(07C1)

Control Axis Deviation

(Δθ)

d-q Axis Devt

Displays the amount of deviation between the actual d-Axis / q-

Axis and the γ-Axis / δ-Axis used for motor control.

10 V: 180 deg

-10 V: -180 deg

(-10 to +10 V)

0.1 deg

U6-13

(07CA)

Flux Position Detection

(sensor)

FluxPosition Fb

Monitors the value of the flux position detection (sensor).

10 V: 180 deg

-10 V: -180 deg

(-10 to +10 V)

0.1 deg

U6-14

(07CB)

Flux Position Estimation

(observer)

FluxPosition Est

Monitors the value of the flux position estimation.

10 V: 180 deg

-10 V: -180 deg

(-10 to +10 V)

0.1 deg

U6-18

(07CD)

Speed Detection PG1

Counter

PG1 CounterValue

Monitors the number of pulses for speed detection (PG1).

10 V: 65536

1 pulse

U6-19

(07E5)

Speed Detection PG2

Counter

PG2 CounterValue

Monitors the number of pulses for speed detection (PG2).

10 V: 65536

1 pulse

U6-20

(07D4)

Frequency Reference

Bias (Up/Down 2)

Up/Dn 2 Bias Val

Displays the bias value used to adjust the frequency reference. 10 V: Max

frequency

0.1%

U6-21

(07D5) Offset Frequency

Offset Frequency

Displays the total value of the offset frequencies d7-01, d7-02

and d7-03 selected with digital inputs 44 to 46.

10 V: Max

frequency

0.1%

U6-22

(0062)

Zero Servo Pulse

Movement

Zero Servo Pulse

Displays how far the rotor has moved from its last position in PG

pulses (multiplied by 4).

10 V: No. of

pulses per

revolution

(-10 to +10 V)

1 pulse

U6-25

(006B)

Feedback Control

Output

ASR Out w/o Fil

Output monitor for the ASR speed loop.

10 V: Motor

secondary rated

current
(-10 to +10 V)

0.01%

U6-26

(006C)

Feed Forward Control

Output

FF Cont Output

Output monitor for Feed Forward control.

10 V: Motor

secondary rated

current
(-10 to +10 V)

0.01%

U6-57

(07C4)

Integrated Current

Deviation during

Judging Polarity

PoleDis IdDifVal

Displays the deviation from the integrated current when judging

motor polarity. If this value is lower than 819, then increase the

value set to n8-84. The value 8192 is equivalent to the motor

rated current.

No signal output

available

1

U6-80 to

U6-83

(07B0H

to 07B3)

<2>

Online IP Address

IP Address currently available; U6-80 is the most significant

octet.

0 to 255

B.13 U: Monitors

342

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide

Advertising