Yaskawa CIMR-AU 200V Drives User Manual
Page 72
Advertising
(2) GROUND
TERMINALS
SECTION B-B
CONTROL CIRCUIT
TERMINALS
MAIN CIRCUIT
TERMINALS
Unit: in. [mm]
0.94
[23.9]
Figure 2.34 Model 4T0072
Table 2.19 12-Pulse Model 4T0072Terminal and Wire Specifications for Main Circuit and Ground
Drive Model
Terminal
Wire Range
AWG, kcmil
Screw
Size
Tightening Torque
N·m (lb.in.)
4T0072
<1>
R/L1, S/L2, T/L3
10 to 3/0 (5.3 to 85.0)
M8
9 to 11
(79.7 to 97.4)
R1/L11, S1/L21, T1/L31
U/T1, V/T2, W/T3
B1, B2
22 to 10 (0.3 to 5.3)
M4
1.2 (10.6)
Refer to applicable codes for wire size
M8
9 to 11
(79.7 to 97.4)
<1> Refer to manual TOEP C710616 50 for information on 12-pulse models.
2.2 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss
72
YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide
Advertising