Yaskawa CIMR-AU 200V Drives User Manual

Page 251

Advertising
background image

u

Three-Phase 200 V Class Drive Models 2A0250 to 2A0415

Table A.4 Power Ratings Continued (Three-Phase 200 V Class)

Item

Specification

Drive Models

2A0250

2A0312

2A0360

2A0415

Maximum Applicable Motor Capacity (HP)

<1>

ND Rating

100

125

150

175

HD Rating

75

100

125

150

Input

Input Current (A)

<2>

ND Rating

271

324

394

471

HD Rating

200

271

324

394

Rated Voltage

Rated Frequency

Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc

<3>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency Fluctuation

±5%

Input Power (kVA)

ND Rating

124

148

180

215

HD Rating

91

124

148

180

Output

Rated Output Capacity (kVA)

<4>

ND Rating

<5>

95

119

137

158

HD Rating

82

<6>

108

<6>

132

<6>

158

<5>

Rated Output Current (A)

ND Rating

<5>

250

312

360

415

HD Rating

215

<6>

283

<6>

346

<6>

415

<5>

Overload Tolerance

ND Rating: 120% of rated output current for 60 s

HD Rating: 150% of rated output current for 60 s

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User adjustable between 1 and 10 kHz

Maximum Output Voltage (V)

Three-phase 200 to 240 Vac (proportional to input voltage)

Maximum Output Frequency (Hz)

400 Hz (user-set)

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring

connections, and power supply impedance.

<3> DC input is not available for UL standards.
<4> Rated motor capacity is calculated with a rated output voltage of 220 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.

A.2 Power Ratings

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide

251

A

Specifications

Advertising