A2: user parameters – Yaskawa CIMR-AU 200V Drives User Manual
Page 266
u
A2: User Parameters
No.
(Addr.
Hex)
Name
LCD Display
Description
Values
Page
A2-01 to
A2-32
(0106 to
0125)
User Parameters 1 to 32 User Param 1 - 32
Recently edited parameters are listed here. The user can also
select parameters to appear here for quicker access.
Default:
<1>
Range: b1-01 to
o4-13
–
A2-33
(0126)
User Parameter
Automatic Selection
User Parms Sel
0: Disabled
1: Enabled
0: Parameters A2-01 to A2-32 are reserved for the user to create
a list of User Parameters.
1: Save history of recently viewed parameters. Recently edited
parameters will be saved to A2-17 through A2-32 for quicker
access.
Default: 1
<2>
Range: 0, 1
–
<1> Default setting value is determined by the Application Preset selected in parameter A1-06.
<2> Default setting value is determined by parameter A1-06. Default is 0 when A1-06 = 0, and 1 when A1-06 ≠ 0.
B.1 A: Initialization Parameters
266
YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide