4 operator programming errors, Operator programming errors – Yaskawa CIMR-AU 200V Drives User Manual

Page 218

Advertising
background image

5.4 Operator Programming Errors

u

Operator Programming Error Codes, Causes, and Possible Solutions

An Operator Programming Error (oPE) occurs when a contradictory parameter is set or an individual parameter is set to an

inappropriate value.
The drive will not operate until the parameter or parameters causing the problem are set correctly. An oPE, however, does not

trigger an alarm or fault output. If an oPE occurs, investigate the cause and refer to

Table 5.4

for the appropriate action. When

an oPE appears on the operator display, press the ENTER button to view U1-18 and see which parameter is causing the oPE.

Table 5.4 oPE Codes, Causes, and Possible Solutions

oPE01

Drive Capacity Setting Fault
Drive capacity and the value set to o2-04 do not match.

oPE02

Parameter Range Setting Error
Use U1-18 to find parameters set outside the range.

oPE03

Multi-Function Input Selection Error
A contradictory setting is assigned to multi-function contact inputs H1-01

to H1-08.

oPE04

Initialization Required

oPE05

Run Command/Frequency Reference Source Selection Error

oPE06

Control Method Selection Error
Correct the setting for the control method.

oPE07

Multi-Function Analog Input Selection Error
A contradictory setting is assigned to multi-function analog inputs H3-02,

H3-10, or H3-06 and PID functions conflict.

oPE08

Parameter Selection Error
A function has been set that cannot be used in the motor control method

selected.

oPE09

PID Control Selection Fault
PID control function selection is incorrect. Requires that PID control is

enabled (b5-01 = 1 to 4).

oPE10

V/f Data Setting Error
One or more of the parameters listed below are not set according to the

formula:
• E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04
• E3-09 ≤ E3-07 < E3-06 ≤ E3-11 ≤ E3-04

oPE11

Carrier Frequency Setting Error
Correct the setting for the carrier frequency.

oPE13

Pulse Monitor Selection Error
Incorrect setting of monitor selection for pulse train (H6-06).

oPE15

Torque Control Setting Error
Parameter settings that are not allowed in combination with Torque Control

have been set.

oPE16

Energy Savings Constants Error

oPE18

Online Tuning Parameter Setting Error
Parameters controlling online tuning are not set correctly.

5.4 Operator Programming Errors

218