Yaskawa CIMR-AU 200V Drives User Manual

Page 294

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

F1-12

(038B) PG 1 Gear Teeth 1

PG1 Gear Teeth1

Sets the gear ratio between the motor shaft and the encoder

(PG).

A gear ratio of 1 will be used if F1-12 or F1-13 are set to 0.

Default: 0

Min.: 0

Max.: 1000

F1-13

(038C) PG 1 Gear Teeth 2

PG1 Gear Teeth2

Sets the gear ratio between the motor shaft and the encoder

(PG). A gear ratio of 1 will be used if F1-12 or F1-13 are set to

0.

Default: 0

Min.: 0

Max.: 1000

F1-14

(038D)

PG Open-Circuit

Detection Time

PGO Detect Time

Sets the time required to trigger a PG Open fault (PGo).

Default: 2.0 s

Min.: 0.0

Max.: 10.0

F1-18

(03AD) dv3 Detection Selection DV3 Det Sel

0: Disabled

n: Number of dv3 occurrences that must be detected to trigger

a dv3 fault.

Default: 10

Min.: 0

Max.: 10

F1-19

(03AE) dv4 Detection Selection DV4 Det Sel

0: Disabled

n: Number of pulses that the A and B pulse are reversed that

triggers dv4 detection.

Default: 128

Min.: 0

Max.: 5000

F1-20

(03B4)

PG Option Card

Disconnect Detection 1

PGCardDisconDet1

0: Disabled

1: Enabled

0: Disabled

1: Enabled

Default: 1

Range: 0, 1

F1-21

(03BC) PG 1 Signal Selection

PG1 Signal Sel 1

0: A Phase Det

1: A,B Phase Det

0: A pulse detection

1: AB pulse detection

Default: 0

Range: 0, 1

F1-30

(03AA)

PG Card Option Port for

Motor 2 Selection

Mtr2 PG Port Sel

0: Port CN5-C

1: Port CN5-B

0: CN5-C

1: CN5-B

Default: 1

Range: 0, 1

F1-31

(03B0)

PG 2 Pulses Per

Revolution

PG2 Pulses/Rev

Sets the number of pulses for a PG option card connected to

port CN5-B.

Default: 1024 ppr

Min.: 1

Max.: 60000

F1-32

(03B1) PG 2 Rotation Selection

PG2 Rotation Sel

0: Fwd = C.C.W

1: Fwd = C.W.

0: Pulse A leads

1: Pulse B leads

Default: 0

Range: 0, 1

F1-33

(03B2) PG 2 Gear Teeth 1

PG2 Gear Teeth1

Sets the gear ratio between the motor shaft and the encoder

(PG).

A gear ratio of 1 will be used if F1-33 or F1-34 are set to 0.

Default: 0

Min.: 0

Max.: 1000

F1-34

(03B3) PG 2 Gear Teeth 2

PG2 Gear Teeth2

Sets the gear ratio between the motor shaft and the encoder

(PG). A gear ratio of 1 will be used if F1-33 or F1-34 are set to

0.

Default: 0

Min.: 0

Max.: 1000

F1-35

(03BE)

PG 2 Division Rate for

Pulse Monitor

PG2 Output Ratio

Sets the division ratio for the pulse monitor used of the PG

option card 2 installed to port CN5-B.

When setting for a three-digit number “xyz”, the division ratio

becomes = [(1 + x) / yz].

Default: 1

Min.: 1

Max.: 132

F1-36

(03B5)

PG Option Card

Disconnect Detection 2

PGCardDisconDet1

0: Disabled

1: Enabled

0: Disabled

1: Enabled

Default: 1

Range: 0, 1

F1-37

(03BD) PG 2 Signal Selection

PG2 Signal Sel

0: A Phase Det

1: A,B Phase Det

0: A pulse detection

1: AB pulse detection

Default: 0

Range: 0, 1

F1-50

(03D2)

<2>

Encoder Selection

Encoder Select

0: EnDat Sin/Cos

1: EnDat SerialOnly

2: Hiperface

Selects the encoder connected the PG-F3 option.

0: EnDat 2.1/01, 2.2/01 Serial Communication + Sin/Cos

1: EnDat 2.2/22 Serial Communication

2: Hiperface

Note:

1. Parameter is not available in models 4A0930

and 4A1200.

2. The use of EnDat2.2/22 encoders requires a

PG-F3 option with software version 0102 or

later. To identify the PG-F3 software version

refer to the PG-F3 label in the field

designated “C/N” (S + four digit number).

Default: 0

Range: 0 to 2

F1-51

(03D3)

<2>

PGoH Detection Level

PGOH Det Level

Sets the level for detecting PG Hardware Fault (PGoH).

Available when F1-20 = 1

Note:

Parameter is not available in models 4A0930 and

4A1200.

Default: 80%

Min.: 1

Max.: 100

B.6 F: Options

294

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide

Advertising