Yaskawa CIMR-AU 200V Drives User Manual

Page 299

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

F6-52

(03C3) DeviceNet PCA Setting PCA Selection

Sets the format of the data set from the DeviceNet master to

the drive.

Default: 21

Min.: 0

Max.: 255

F6-53

(03C4) DeviceNet PPA Setting PPA Selection

Sets the format of the data set from the drive to the DeviceNet

master.

Default: 71

Min.: 0

Max.: 255

F6-54

(03C5)

DeviceNet Idle Mode

Fault Detection

DN Idle Flt Det

0: Stop

1: Ignore

0: Enabled

1: Disabled, no fault detection

Default: 0

Range: 0, 1

F6-55

(03C6)

DeviceNet Baud Rate

Monitor

DN BAUD RATE

MEM

0: 125 kbps

1: 250 kbps

2: 500 kbps

Verifies the baud rate running on the network.

0: 125 kbps

1: 250 kbps

2: 500 kbps

Default: 0

Range: 0 to 2

F6-56

(03D7)

DeviceNet Speed

Scaling

Speed Scale

Sets the scaling factor for the speed monitor in DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-57

(03D8)

DeviceNet Current

Scaling

Current Scale

Sets the scaling factor for the output current monitor in

DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-58

(03D9)

DeviceNet Torque

Scaling

Torque Scale

Sets the scaling factor for the torque monitor in DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-59

(03DA)

DeviceNet Power

Scaling

Power Scale

Sets the scaling factor for the power monitor in DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-60

(03DB)

DeviceNet Voltage

Scaling

Voltage Scale

Sets the scaling factor for the voltage monitor in DeviceNet. Default: 0

Min.: -15

Max.: 15

F6-61

(03DC) DeviceNet Time Scaling Time Scale

Sets the scaling factor for the time monitor in DeviceNet.

Default: 0

Min.: -15

Max.: 15

F6-62

(03DD)

DeviceNet Heartbeat

Interval

DN Heart Beat

Sets the heartbeat interval for DeviceNet communications.

Default: 0

Min.: 0

Max.: 10

F6-63

(03DE)

DeviceNet Network

MAC ID

DN MAC ID MEM

Saves and monitors settings 0 to 63 of F6-50 (DeviceNet MAC

Address).

Default: 63

Min.: 0

Max.: 63

F6-64 to

F6-71

(03DF to

03C8)

Reserved

Reserved for Dynamic I/O Assembly Parameters.

F6-72

(03DE)

PowerLink Node

Address

PowerLink NodeID

Reserved.

<1> Parameter setting value is not reset to the default value when the drive is initialized.
<2> Values shown are for the MECHATROLINK-II option (SI-T3). Values for MECHATROLINK-III option (SI-ET3) are:

Min: 03
Max.: EF

<3> Values shown are for the MECHATROLINK-II option (SI-T3). Values for MECHATROLINK-III option (SI-ET3) are:

0: 64-byte
1: 32-byte

B.6 F: Options

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide

299

B

Parameter List