Flange type heat loss data – Yaskawa CIMR-AU 200V Drives User Manual
Page 42
n
Flange Type Heat Loss Data
Table 2.10 Models 2A0004 to 2A0012, 4A0002 to 4A0005, and 5A0003 and 5A0004
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc = 8 kHz)
Internal
External
Total
Internal
External
Total
2A0004
200
47.3
18.4
65.7
44.4
14.8
59.2
3.3 (7.3)
2A0006
51.4
30.8
82.2
47.6
24.1
71.7
3.3 (7.3)
2A0008
52.1
42.9
95.0
48.9
34.8
83.7
3.4 (7.5)
2A0010
58.4
56.7
115.1
52.1
42.9
95.0
3.4 (7.5)
2A0012
64.4
76.9
141.3
57.9
63.7
121.6
3.4 (7.5)
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc = 8 kHz)
Internal
External
Total
Internal
External
Total
4A0002
400
47.9
19.8
67.7
44.7
15.9
60.6
3.4 (7.5)
4A0004
49.2
32.1
81.3
45.7
24.6
70.3
3.4 (7.5)
4A0005
52.8
44.6
97.4
49.4
37.4
86.8
3.4 (7.5)
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc = 8 kHz)
Internal
External
Total
Internal
External
Total
5A0003
600
23.3
21.5
44.8
19.8
28.9
48.7
3.4 (7.5)
5A0004
33.6
27.5
61.1
27.6
54.3
81.9
3.4 (7.5)
2.2 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss
42
YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide