Three-Phase 200 V Class Drive Models 2A0040 to 2A0211

Table A.3 Power Ratings Continued (Three-Phase 200 V Class)

Item

Specification

Drive Model

2A0040 2A0056 2A0069 2A0081 2A0110 2A0138 2A0169 2A0211

Maximum Applicable Motor Capacity

(HP)

<1>

ND Rating

15

20

25

30

40

50

60

75

HD Rating

10

15

20

25

30

40

50

60

Input

Input Current (A)

<2>

ND Rating

52

68

80

92

111

136

164

200

HD Rating

37

52

68

80

82

111

136

164

Rated Voltage

Rated Frequency

Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc

<3>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency Fluctuation

±5%

Input Power (kVA)

ND Rating

24

31

37

42

51

62

75

91

HD Rating

17

24

31

37

37

51

62

75

Output

Rated Output Capacity

(kVA)

<4>

ND Rating

<5>

15.2

21

26

31

42

53

64

80

HD Rating

12.6

<6>

17.9

<6>

23

<6>

29

<6>

32

<6>

44

<6>

55

<7>

69

<7>

Rated Output Current (A)

ND Rating

<5>

40

56

69

81

110

138

169

211

HD Rating

33

<6>

47

<6>

60

<6>

75

<6>

85

<6>

115

<6>

145

<7>

180

<7>

Overload Tolerance

ND Rating: 120% of rated output current for 60 s

HD Rating: 150% of rated output current for 60 s

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

User adjustable between 1 and 15 kHz

User adjustable

between 1 and

10 kHz

Maximum Output Voltage (V)

Three-phase 200 to 240 Vac (proportional to input voltage)

Maximum Output Frequency (Hz)

400 Hz (user-set)

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring

connections, and power supply impedance.

<3> DC input is not available for UL standards.
<4> Rated motor capacity is calculated with a rated output voltage of 220 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased to 8 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<7> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.

A.2 Power Ratings

250

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide

Advertising