D7: offset frequency – Yaskawa CIMR-AU 200V Drives User Manual
Page 285
u
d7: Offset Frequency
No.
(Addr.
Hex)
Name
LCD Display
Description
Setting
Page
d7-01
(02B2) Offset Frequency 1
Offset Freq 1
Added to the frequency reference when the digital input
“Frequency offset 1” (H1-oo = 44) is switched on. A setting
of 100% is equal to the drive maximum output current.
Default: 0.0%
Min.: -100.0
Max.: 100.0
–
d7-02
(02B3) Offset Frequency 2
Offset Freq 2
Added to the frequency reference when the digital input
“Frequency offset 2” (H1-oo = 45) is switched on. A setting
of 100% is equal to the drive maximum output current.
Default: 0.0%
Min.: -100.0
Max.: 100.0
–
d7-03
(02B4) Offset Frequency 3
Offset Freq 3
Added to the frequency reference when the digital input
“Frequency offset 3” (H1-oo = 46) is switched on. A setting
of 100% is equal to the drive maximum output current.
Default: 0.0%
Min.: -100.0
Max.: 100.0
–
B.4 d: References
YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide
285
B
Parameter List