Three-phase 600 v – Yaskawa CIMR-AU 200V Drives User Manual
Page 25

n
Three-Phase 600 V
Table 1.3 Model Number and Specifications (600 V)
Normal Duty (ND)
C6-01 = 1
Heavy Duty (HD)
C6-01 = 0
Drive Model
Max. Motor Capacity
kW (HP)
Rated Output
Current A
Drive Model
Max. Motor Capacity
kW (HP)
Rated Output
Current A
5A0003
1.5 (2)
2.7
5A0003
0.75 (1)
1.7
5A0004
2.2 (3)
3.9
5A0004
1.5 (2)
3.5
5A0006
3.7 (5)
6.1
5A0006
2.2 (3)
4.1
5A0009
5.5 (7.5)
9
5A0009
3.7 (5)
6.3
5A0011
7.5 (10)
11
5A0011
5.5 (7.5)
9.8
5A0017
11 (15)
17
5A0017
7.5 (10)
12.5
5A0022
15 (20)
22
5A0022
11 (15)
17
5A0027
18.5 (25)
27
5A0027
15 (20)
22
5A0032
22 (30)
32
5A0032
18.5 (25)
27
5A0041
30 (40)
41
5A0041
22 (25-30)
32
5A0052
37 (50)
52
5A0052
30 (40)
41
5A0062
45 (60)
62
5A0062
37 (50-60)
52
5A0077
55 (75)
77
5A0077
45 (50-60)
62
5A0099
75 (100)
99
5A0099
55 (75)
77
5A0125
90 (125)
125
5A0125
75 (100)
99
5A0145
110 (150)
145
5A0145
90 (125)
130
5A0192
160 (200)
192
5A0192
110 (150)
172
5A0242
185 (250)
242
5A0242
160 (200)
200
1.1 Model Number and Nameplate Check
YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide
25
1
Receiving