Flange type models 4a0515 and 4a0675, Flange type exterior and mounting dimensions, Flange type heat loss data – Yaskawa CIMR-AU 200V Drives User Manual
Page 98
u
Flange Type Models 4A0515 and 4A0675
n
Flange Type Exterior and Mounting Dimensions
NOTE: Maximum surrounding air temperature is 50 °C (122 °F)
Unit: in. [mm]
NOTE: Spreader bar required to avoid damage during lifting.
LIFTING AND EYEBOLT DETAILS
(3) EXTERNAL
COOLING FANS
(20)-MOUNTING HOLES
FOR 3/8 in. [M10] SCREWS
HORIZONTAL MOUNTING DIM
M122 THREAD
VER
TICAL
MOUNTING DIM
(2) MOUNTING BRACKETS
USED DURING TRANSPORT ONLY
REMOVE BEFORE INSTALLING
AIR
AIR
FRONT VIEW
Figure 2.57 Models 4A0515 and 4A0675
n
Flange Type Heat Loss Data
Table 2.29 Models 4A0515 and 4A0675
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc = 8 kHz)
Internal
External
Total
Internal
External
Total
4A0515
400
1668
4850
6518
1386
3972
5358
223 (492)
4A0675
2037
4861
6898
1685
4191
5876
228 (503)
2.2 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss
98