Optimisation of the operating behaviour

The following settings are used to determine the current and torque behaviour as
well as the performance of the connected motor.

Choose

between

the

control

modes

”Motor

current

control”

and

”V/f-characteristic control”. Information to help you with the selection can be
obtained from chapter 5.4.1.

5.4.1

Select control mode

Code

Name

Possible settings

IMPORTANT

Lenze

Choice

Info

C014

¤ Control mode

Control modes
of the voltage
characteristic

820X

-0-

-0-

Linear characteristic V

f

d

with

auto boost

-1-

Square characteristic V

f

d

2

with

auto boost

-2-

Linear characteristic V

f

d

with

constant V

min

boost

-3-

Square characteristic V

f

d

2

with

constant V

min

boost

821X/822X/

824X

-4-

-4-

Motor-current control

Function

-

Under C014 you can set the control mode and the voltage characteristic.

-

The V/f-characteristic control with auto boost enables a low-loss operation of stand-alone drives
with standard three-phase AC motors with load-dependent V

min

boost.

-

The motor-current control enables a ”Sensorless Speed Control”. Compared to the
V/f-characteristic control, the drive can operate with a considerably higher torque and less current
consumption during idle running.

C014 = -2-
Linear characteristic

C014 = -3-
Square characteristic (e.g. for pumps, fans)

1 0 0 %

0

0

1

f d

f d r

m i n

0

0

1

f d

f d r

m i n

1 0 0 %

V

V

V o u t

V o u t