3 connection of a brake unit, Connection of a brake unit, Installation – Lenze 8200 Frequency inverters User Manual

Page 91

Advertising
background image

Installation

8200SHB0199

4-34

4.2.7.3

Connection of a brake unit

-

When connecting a brake unit (brake module with internal brake resistor or
brake chopper with external brake resistor) observe the corresponding
Operating Instructions in all cases.

Stop!

-

Design the circuit so that, if the temperature monitoring of the brake unit is
activated,

- the controllers are inhibited (X5/28 = LOW),

- the mains is disconnected.