8 motor data detection, Motor data detection, Configuration – Lenze 8200 Frequency inverters User Manual

Page 164

Advertising
background image

Configuration

8200SHB0199

7-27

7.5.8

Motor data detection

820X setting range:

Function not available.

Setting range 821X/822X/824X:

Code

Name

Possible settings

IMPORTANT

Lenze

Choice

Info

C088 Rated motor current

821X/822X/824X

*

0.0 ... 1.2

k rated output current

0.0 ... 2.0

k rated output current

HVAC only

*depends on the unit

C091 Motor cos

j

821X/822X/824X

*

0.4

{0.1}

1.0

*depends on the unit

Function

Is used to adapt not matching motors, special motors, etc.

Adjustment

Enter the rated currrent and cos

j of your motor.

Important

-

The motor data detection is only effective with the control mode C014 = -4-.

-

Drives with matching 4 pole standard motors 230/400 V in star connection do not need to be
adapted. After having started the drive, the controller itself detects all further motor data.

-

The following drives can be optimised by entering the nameplate data ”rated motor current” and
”cos

j” under C088 or C091:

- Motor, one power class smaller than the motor assigned to the controller.
- Motor, one or two power classes smaller than the motor assigned to the controller.
- Drives with 2, 6, 8, 10 and 12 pole standard motors.
- Drives with special motors.