Configuration

8200SHB0199

7-20

820X
821X
822X
824X

V/f-characteristic control with V

min

boost

Select the classical V/f-control with constant V

min

boost to operate the following drives:

-

Multi-motor applications (several motors connected to one controller)

-

Three-phase AC reluctance motors

-

Three-phase sliding rotor motors

-

Operation with special motors with assigned frequency-voltage characteristic

-

Positioning and infeed drives with high dynamic response

-

Hoists

C014 = -2-
Linear characteristic

C014 = -3-
Square characteristic
(e.g. for pumps, fans)

1 0 0 %

0

0

1

f d

f d r

m i n

0

0

1

f d

f d r

m i n

1 0 0 %

V

V

V o u t

V o u t

821X
822X
824X

Motor-current control
Compared with the V/f-characteristic control the motor-current control offers considerably higher
torque and reduced current consumption during idle running. Select the motor-current control for
operation with the following drives:

-

Single drives with extremely variable loads

-

Single drives with heavy start conditions

-

Multi-motor applications with the same motors and the same load distribution

-

Sensorless speed control of standard three-phase AC motors together with slip compensation
(C021)