Configuration – Lenze 8200 Frequency inverters User Manual

Page 225

Advertising
background image

Configuration

8200SHB0199

7-88

Code

IMPORTANT

Possible settings

Name

Code

IMPORTANT

Info

Choice

Lenze

Name

C008

¤ Function relay K1

-1-

-0-

Ready for operation

-1-

TRIP fault message

-2-

Motor is running

-3-

Motor is running / CW rotation

-4-

Motor is running / CCW rotation

-5-

Field frequency f

d

= 0

-6-

f

dset

reached

-7-

Q

min

reached

-8-

I

max

reached

-9-

Overtemperature (

J

max

-10

•C)

-10-

TRIP or Q

min

or IMP

Page 7-65

822X/824X

-11-

PTC warning

-12-

Apparent motor current
(C054) < threshold C156

-13-

Apparent motor current
(C054) < current threshold C156
and f

d

> Q

min

threshold (C017)

-14-

Apparent motor current
(C054) < threshold C156 and input
of ramp function generator =
output of ramp function generator

822X/824X

-15-

Warning motor phase failure

-16-

f

d

(C050) < f

dmin

(C010)

C009*

¤ Device address

1

1

{1}

99

Only for LECOM
applications

C010

œ Minimum field

frequency

0.00

0.00

{0.02 Hz}

480.00 Page 7-15

C011

œ Maximum field

frequency

50.00

7.50

{0.02 Hz}

480.00 Page 7-15

C012 Acceleration time T

ir

5.00

0.00

{0.02 s}

1300.00 Page 7-16

C013 Deceleration time T

if

5.00

0.00

{0.02 s}

1300.00 Page 7-16,

7-55

C014

¤ Control mode

-4-

-2-

Linear characteristic V

f

d

with

constant V

min

boost

-3-

Square characteristic V f

d

2

with

Page 7-19,

7-22, 7-24

-3-

Square characteristic V

f

d

2

with

constant V

min

boost

constant V

min

boost

-4-

Motor-current control

C015 V/f rated frequency

50.00

7.50

{0.02 Hz}

960.00 Page 7-22

C016 V

min

setting

*

0.00

{0.02 %}

40.00 Page 7-24

*depends on the unit

C017

œ Threshold Q

min

0.00

0.00

{0.02 Hz}

480.00 Page 7-65

C018

¤ Chopper frequency

-1-

-0-

4 kHz power-loss optimised

-1-

8 kHz, power-loss optimised

-2-

12 kHz power-loss optimised

-3-

16 kHz power-loss optimised

-4-

4 kHz noise optimised

Page 7-29

-3-

16 kHz power-loss optimised

-4-

4 kHz noise optimised

-5-

8 kHz noise optimised

-6-

12 kHz noise optimised

-7-

16 kHz noise optimised

C019

œ Threshold auto DC

brake

0.10

0.00

{0.02 Hz}

5.00 Page 7-56

Show/Hide Bookmarks

Advertising