Technical Data

8200SHB0199

3-20

3.5.4

Types 824X

120 % overload

Type

8241

8242

8243

8244

8245

8246

Mains current
with mains filter/mains choke

I

mains

[A]

1.7

2.8

5.0

8.8

15.0

20.5

Data for mains operation with 3 AC / 400 V / 50 Hz/60 Hz ; 460 V

$ V

DC

$ 620 V

Motor power (4 pole ASM)
at 4 kHz/8 kHz

*

P

r

[kW]

0.55

1.1

2.2

4.0

7.5

11.0

Motor power (4 pole ASM)
at 4 kHz/8 kHz

*

P

r

[hp]

0.75

1.5

2.9

5.4

10.0

15.0

Output power U, V, W
at 4 kHz/8 kHz

*

S

r4

[kVA]

S

r8

[kVA]

1.3
1.0

2.1
1.7

3.8
2.7

6.5
4.8

11.1

9.0

16.3
16.3

Output
current

4 kHz

*

I

r4

[A]

1.8

3.1

5.5

9.2

16.0

23.5

Output
current

8 kHz

*

I

r8

[A]

1.5

2.5

3.9

7.0

13.0

23.5

12 kHz

*

I

r12

[A]

1.35

2.2

3.5

6.3

11.7

20.0

16 kHz

*

I

r16

[A]

1.2

2.0

3.1

5.6

10.4

16.5

Noise optimised 4 kHz

*2)

I

r4

[A]

1.5

2.5

3.9

7.0

13.0

23.5

Noise optimised 8 kHz

*2)

I

r8

[A]

1.3

2.2

2.9

6.0

11.1

20.0

Noise optimised 12 kHz

*

I

r12

[A]

1.3

2.1

3.4

6.1

11.3

19.4

Noise optimised 16 kHz

*

I

r16

[A]

1.1

1.8

2.9

5.2

9.7

15.2

Max.
output

I

rmax4

[A]

2.25

3.6

6.6

11.0

19.5

35.3

Max.
output
current

8 kHz

*

I

r8

[A]

2.2

3.7

5.8

10.5

19.5

35

current
for

12 kHz

*

I

r12

[A]

2.0

3.3

5.2

9.5

17.5

30.0

for
60 s

1)

16 kHz

*

I

r16

[A]

1.8

3.0

4.7

8.4

15.6

24.6

60 s

1)

Noise optimised 4 kHz

*2)

I

r4

[A]

2.3

3.8

5.8

10.5

19.5

35.5

Noise optimised 8 kHz

*2)

I

r8

[A]

2.0

3.2

5.0

7.8

14.5

22.9

Noise optimised 12 kHz

*

I

r12

[A]

1.9

3.2

5.1

9.1

16.5

29.0

Noise optimised 16 kHz

*

I

r16

[A]

1.6

2.7

4.3

7.8

14.5

22.9

Power loss (operation with I

rx

)

P

loss

[W]

50

65

115

165

260

360

1)

The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned here and
2 minutes base load with 75 % I

rx

.

2)

Only with variant “HVAC”

*

Chopper frequency of the inverter

For more data see chapter 3.4.6 and chapter 3.4.7.