Configuration – Lenze 8200 Frequency inverters User Manual

Page 227

Advertising
background image

Configuration

8200SHB0199

7-90

Code

IMPORTANT

Possible settings

Name

Code

IMPORTANT

Info

Choice

Lenze

Name

C070 Gain PID controller

1.00

0.00

{0.01}

300.00 Page 7-34

0.0 = P-component
not active

C071 Integral action time

PID controller

100

10

9999 Page 7-34

9999 = I-component
not active

C072 Differential

component of PID
controller

0.0

0.0

{0.1}

5.0 Page 7-34

0.0 = D-component
not active

C074 Influence PID

controller

0.0

0.0

{0.1 %}

100.0 Page 7-34

C077* Gain I

max

controller

0.25

0.00

{0.01}

1.00 Page 7-18

C078* Integral action time

I

max

controller

65

12

{1 ms}

9990 Page 7-18

C079 Oscillation damping

*

Page 7-31

C079

822X/824X

5

0

{1}

80

C088 Rated motor current

*

0

{1 A}

480

0.0 ... 2.0

k rated output current

Page 7-27

*depends on the unit

C091 Motor cos

j

*

0.4

{0.1}

1.0

Page 7-27

C093* Type

Page 7-64

C093*

821X

821X

822X

822X

Display only

824X

824X

Display only

C099* Software version

82 3x

(Software 3x)

Page 7-64

C105 Deceleration time

QSP

5.00

0.00

{0.02 s}

1300.00

Page 7-55

C106 Holding time for

autom. DC injection
brake

0.02

0.00

{0.01 s}

999.00 Page 7-56

C108* Gain (C111)

128

0

{1}

255 Page 7-69

Show/Hide Bookmarks