Configuration – Lenze 8200 Frequency inverters User Manual
Page 227
Configuration
8200SHB0199
7-90
Code
IMPORTANT
Possible settings
Name
Code
IMPORTANT
Info
Choice
Lenze
Name
C070 Gain PID controller
1.00
0.00
{0.01}
300.00 Page 7-34
0.0 = P-component
not active
C071 Integral action time
PID controller
100
10
9999 Page 7-34
9999 = I-component
not active
C072 Differential
component of PID
controller
0.0
0.0
{0.1}
5.0 Page 7-34
0.0 = D-component
not active
C074 Influence PID
controller
0.0
0.0
{0.1 %}
100.0 Page 7-34
C077* Gain I
max
controller
0.25
0.00
{0.01}
1.00 Page 7-18
C078* Integral action time
I
max
controller
65
12
{1 ms}
9990 Page 7-18
C079 Oscillation damping
*
Page 7-31
C079
822X/824X
5
0
{1}
80
C088 Rated motor current
*
0
{1 A}
480
0.0 ... 2.0
k rated output current
Page 7-27
*depends on the unit
C091 Motor cos
j
*
0.4
{0.1}
1.0
Page 7-27
C093* Type
Page 7-64
C093*
821X
821X
822X
822X
Display only
824X
824X
Display only
C099* Software version
82 3x
(Software 3x)
Page 7-64
C105 Deceleration time
QSP
5.00
0.00
{0.02 s}
1300.00
Page 7-55
C106 Holding time for
autom. DC injection
brake
0.02
0.00
{0.01 s}
999.00 Page 7-56
C108* Gain (C111)
128
0
{1}
255 Page 7-69
Show/Hide Bookmarks