Configuration – Lenze 8200 Frequency inverters User Manual

Page 140

Advertising
background image

Configuration

8200SHB0199

7-3

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

Key functions
”SH + ” means:
1.Press and hold key SH.
2.Press second key indicated.

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

Key

Function

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

PRG

Change between operating and code level

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

SH

Change between code and parameter level

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

Increase display value

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

Decrease display value

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

SH + ▲

Increase display value rapidly

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

SH + ▼

Decrease display value rapidly

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

SH + PRG

Store changes
(each parameter can be stored individually before mains disconnection)

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

STP

Inhibit controller

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

RUN

Enable controller

S H

PRG

S TP

RUN

PAR2 0VLVIMAXDBTEMP

PAR1

LOAD

SET

A

%

Hz

Status display
(For fault messages see chapter 8)
Display

Meaning

OV

Overvoltage

LV

Undervoltage

IMAX

Current limit exceeded

TEMP

Heat sink temperature near switch-off (

J

max

-10

•C)

PAR1

Parameter set 1 active, PAR1 blinking: Programming possible

PAR2

Parameter set 2 active, PAR2 blinking: Programming possible

SET

Setpoint input via keypad

5-digit, 7-segment display
Display

Meaning

OFF

Controller inhibited by a LOW signal at terminal 28

STOP

Controller inhibited (by STP key or quick stop function or field frequency
f

d

= 0 Hz)

AS_LC

Autostart-Lockout, controller will only be enabled after a low-high edge at
terminal 28.

STO

The parameter will be stored.

dC_b

DC injection brake active

LU

Undervoltage

SET1

Parameter set 1 will be overwritten with the factory setting.

SET2

Parameter set 2 will be overwritten with the factory setting.

rEAd1

Parameter set 1 will be overwritten with the data of the operating module.

rEAd2

Parameter set 2 will be overwritten with the data of the operating module.

STOE

The parameter sets PAR1 and PAR2 will be transferred to the operating
module.

Bar-graph display
The bottom line of the LCD shows the controller load:

L O A D

L O A D
L O A D

L O A D

L O A D

g e n e r a t i v e
n o

2 0 %

4 0 %

1 0 0 %

8 0 %

6 0 %

1 6 0 %

L O A D
L O A D
L O A D

l o a d

o v e r l o a d

l o a d

l o a d

l o a d

l o a d

l o a d

l o a d

FIG 7-1

8201BB operating modules - functions, displays

Show/Hide Bookmarks