2 priority mask for digital inputs, Priority mask for digital inputs, Configuration – Lenze 8200 Frequency inverters User Manual

Page 190: Only “hvac” controllers

Advertising
background image

Configuration

8200SHB0199

7-53

7.5.14.2 Priority mask for digital inputs

Only “HVAC” controllers

Code

Name

Possible settings

IMPORTANT

Lenze

Choice

Info

C115

¤ Priority mask digital

inputs

-0-

E4

E3

E2

E1

-0-

0

0

0

0

-1-

0

0

0

1

-2-

0

0

1

0

-3-

0

0

1

1

-4-

0

1

0

0

-5-

0

1

0

1

-6-

0

1

1

0

-7-

0

1

1

1

-8-

1

0

0

0

-9-

1

0

0

1

-10-

1

0

1

0

-11-

1

0

1

1

-12-

1

1

0

0

-13-

1

1

0

1

-14-

1

1

1

0

-15-

1

1

1

1

0: Function Ex
depends on C001
1: Function Ex is
independent of C001

Function

-

Independently of the operating mode C001 = -3- (control via LECOM), it is possible to activate
additional digital inputs.
- It is now possible to use additional control functions via terminals E1 ... E4. The signals are

assigned by means of an OR link.

-

C115 = -0- is always active with terminal configuration (C007) with manual/remote changeover.

Adjustment

Example
The DC injection brake is to be activated via terminal 3:

-

Operating mode C001 = -3- (control via LECOM).

-

Terminal configuration C007 = -0-.

Solution:

-

Set the priority mask C115 = -4-
- The DC injection brake can now be activated via terminal E3.

Important

-

Controller inhibit and TRIP reset always have priority.

-

With C115 = -0-, also TRIP set and QSP have priority.