During operation

8200SHB0199

6-1

6

During operation

6.1

Operating information

6.1.1

General

-

Replace defective fuses with the prescribed type only when no voltage is
applied.
There are no fuses in the controller.

-

With cyclic mains connection and disconnection:

- Do not switch on the controller more than every three minutes, otherwise

the internal initial-current limitation can be overloaded.

-

Switching on the motor side:

- Permissible for emergency switch-off.

- Monitoring messages can be activated when switching the motor when

the controller is enabled.

-

The plug-in connection terminals of the 820X controllers must only be
connected or disconnected when no voltage is applied.

-

Depending on the controller settings, the connected motor can be
overheated:

- For instance, longer DC-braking operations.

- Longer operation of self-ventilated motors at low speed.

-

With the corresponding parameter setting, the controllers reach an output
frequency of up to 480 Hz:

- If an inappropriate motor is connected, a hazardous overspeed may

occur.

- With frequencies > 240 Hz, the overcurrent switch-off of the 820X

controllers can be activated.

-

With the function CW/CCW (selection of the direction of rotation) in
configuration C007 = -0- ... -13-, -23 ... -45-:

- The drive can reverse the direction of rotation in the event of a

control-voltage failure or a cable break.

-

If the function ”flying-restart circuit” (C142 = -2-, -3-) is used with machines
with low inertia torque and friction:

- After the controller has been enabled in standstill, the motor can start for a

short time or reverse the direction of rotation.