3 selection basics, 1 conditions, Selection basics – Lenze 8200 Frequency inverters User Manual

Page 252: Conditions, Network of several drives

Advertising
background image

Network of several drives

8200SHB0199

10-9

10.3

Selection basics

In the following table you will find some basic data to select a drive network. Two
examples explain the use of the tables.

10.3.1

Conditions

The unit data list in the table TAB 1 are only valid, if the network fulfills the following
conditions:

-

All inputs are connected to the three-phase AC mains by means of the
mains filters prescribed in TAB 2.

-

Chopper frequencies:

- 93XX: 8 kHz.

- 821X/822X/824X: 4 kHz or 8 kHz.

-

Motors (three-phase AC asynchronous motors, asynchronous servo motor,
synchronous servo motors):

- Simultaneity factor F

g

= 1, i.e. all motors operate simultaneously with

100 % motor load.

- Mains voltage V

mains

= 400 V / 50 Hz

- Ambient temperature during operation: max. +40

E

C

Show/Hide Bookmarks