7.5.9.3

Oscillation damping

Setting range 820X/821X:

Function not available.

Setting range 822X/824X:

Code

Name

Possible settings

IMPORTANT

Lenze

Choice

Info

C079 Oscillation damping

Is not transferred when
transferring
parameters via the

822X/824X

5

0

{1}

80

transferring
parameters via the
operating module.

Function

Suppression of idling oscillations when:

-

a drive does not match, i.e. rated controller power - motor
e.g. operation with high chopper frequency and the related power derating,

-

operation of higher-pole motors,

-

operation of special motors,

-

having a resonance phenomenon in the drive set.

Adjustment

1.Approach the area with speed oscillations.
2.Reduce the oscillation by changing C079 step by step.

- Indicators for smooth running can be a uniform motor current or the reduction of the

mechanical vibrations in the bearing seat.

Important

-

Parameter transfer from C079 not possible via keypad.

-

Compensate the resonances in speed controlled operation via the parameters of the controller.