Installation

8200SHB0199

4-2

Possible mounting positions for types 8201 to 8214

-

In vertical position at the back of the control cabinet, terminals point to the
front:

- With attached fixing rails.

- With special fixing unit on one or two DIN rails.

-

Turned by 90

•

(flast assembly on the backside of the control cabinet):

- Insert the attached fixing rail into the guides at the heat sink.

-

Horizontally with an additional fan.

-

On a pivoting frame for assembly depths < 198 mm:

- Therefore easy handling and installation of the front interfaces possible.

Possible mounting positions for types 8215 to 8218

-

In vertical position at the back of the control cabinet, terminals point to the
front:

- With attached fixing rails.

- Thermally separated with external heat sink (”push-through technique”).

- Variant V003 thermally separated with external cooler in ”Cold plate”

technique (e.g. with convection cooler).

Possible mounting positions types 822X/824X

-

In vertical position at the back of the control cabinet, terminals point to the
front:

- With attached fixing brackets.

- Thermally separated with external heat sink (”push-through technique”).

- Variant V003 thermally separated with external cooler in ”Cold plate”

technique (e.g. with convection cooler).