Configuration

8200SHB0199

7-50

7.5.14

Function of the inputs to be configured block by block

C007

E1

E2

E3

E4

-0-

JOG 1, JOG 2, JOG 3

DC injection brake

CW/CCW

-1-

JOG 1, JOG 2, JOG 3

PAR

CW/CCW

-2-

JOG 1, JOG 2, JOG 3

QSP

CW/CCW

-3-

JOG 1

DC injection brake

PAR

CW/CCW

-4-

JOG 1

PAR

QSP

CW/CCW

-5-

JOG 1

TRIP set

DC injection brake

CW/CCW

-6-

JOG 1

TRIP set

PAR

CW/CCW

-7-

TRIP set

DC injection brake

PAR

CW/CCW

-8-

TRIP set

PAR

QSP

CW/CCW

-9-

JOG 1

TRIP set

QSP

CW/CCW

-10-

DOWN

UP

TRIP set

CW/CCW

-11-

DOWN

UP

DC injection brake

CW/CCW

-12-

DOWN

UP

PAR

CW/CCW

-13-

DOWN

UP

QSP

CW/CCW

-14-

JOG 1

DC injection brake

CW/QSP

CCW/QSP

-15-

JOG 1

PAR

CW/QSP

CCW/QSP

-16-

JOG 1, JOG 2, JOG 3

CW/QSP

CCW/QSP

-17-

DC injection brake

PAR

CW/QSP

CCW/QSP

-18-

TRIP set

PAR

CW/QSP

CCW/QSP

-19-

TRIP set

DC injection brake

CW/QSP

CCW/QSP

-20-

JOG 1

TRIP set

CW/QSP

CCW/QSP

-21-

DOWN

UP

CW/QSP

CCW/QSP

-22-

JOG 1

UP

CW/QSP

CCW/QSP

only

series “HVAC”

-23-

DOWN

UP

CW/CCW

H/RE

only

series “HVAC”

-24-

DOWN

UP

PAR

H/RE

-25-

DOWN

UP

DC injection brake

H/RE

-26-

DOWN

UP

JOG1

H/RE

-27-

DOWN

UP

TRIP set

H/RE

-28-

D/F

I-OFF

JOG 1, JOG 2, JOG 3

-29-

D/F

I-OFF

DC injection brake

JOG 1

-30-

D/F

I-OFF

QSP

JOG 1

-31-

D/F

I-OFF

QSP

DC injection brake

-32-

D/F

I-OFF

QSP

TRIP set

-33-

D/F

I-OFF

PAR

QSP

-34-

D/F

I-OFF

CW/QSP

CCW/QSP

-35-

D/F

PAR

JOG 1, JOG 2, JOG 3

-36-

D/F

PAR

QSP

CCW/QSP

-37-

D/F

PAR

QSP

CCW/QSP

-38-

D/F

TRIP set

PAR

CCW/QSP

-39-

D/F

TRIP set

JOG 1, JOG 2, JOG 3

Show/Hide Bookmarks