Central supply

The DC-bus is supplied via a central supply source. Supply sources are:

-

DC source - 820X.

-

Supply and feedback module - 821X/822X/824X/93XX.

-

Controller with reserve power.

10.4.1

Central supply of 820X

820X

U

V W

PE

L1

N -UG +UG

820X

U

V W

PE

L1

N -UG +UG

Z3

F5

-UG +UG

820xAB

+UG

-UG

F5

820xAB

PE

PE

F4

F4

FIG 10-2

Block diagram: Central supply of several 820X controllers connected to a network

F4, F5

Fuses, DC level, see Accessories

Z3

Brake chopper/brake module, see Accessories

820XAB

Current-limitation module, see Accessories

Stop!

For faultless network operation, the following conditions must be fulfilled in addition
to the conditions described in chapter 10.2:

-

The voltage flow +U

G

“

PE / -U

G

“

PE must be symmetrical!

- The controller will be destroyed, if +U

G

or -U

G

are grounded.

-

Use the current limitation module 820XAB.