2 features, Features, Technical data – Lenze 8200 Frequency inverters User Manual

Page 34

Advertising
background image

Technical Data

8200SHB0199

3-2

3.2

Features

820X

821X

822X

824X

Compact design

/

/

/

/

Load capacity of up to 150 % I

r

for 1 min

/

/

/

/

Inverter outputs are protected against short circuit

/

/

/

/

Earth-fault check at mains connection

/

/

/

/

Chopper frequency 9.2 kHz

/

Chopper frequency selectable: 4 kHz, 8 kHz, 12 kHz, 16 kHz

/

/

/

V/f-characteristic control with constant V

min

boost or auto boost

/

Motor-current control or V/f-characteristic control selectable

/

/

/

Mains-voltage compensation

/

/

/

/

Slip compensation

/

/

/

/

Adjustable current limitation with V/f-override

/

/

/

/

PWM converter with IGBT-power stages

/

/

/

/

DC-bus connection and brake-chopper connection

/

/

/

/

Isolated analog input and output

/

/

/

/

Relay outputs (change-over contact)

1

1

2

2

PLC-compatible digital outputs (I/O module 8275)

3 (option)

3 (option)

3 (option)

3 (option)

Isolated digital inputs with programmable functions

4

4

4

4

Up to 3 JOG frequencies per parameter set

/

/

/

/

DC-injection brake

/

/

/

/

TRIP set and TRIP reset function

/

/

/

/

Motor potentiometer

/

/

/

/

Output frequency up to 240 Hz / 480 Hz

/

Output frequency up to 480 Hz

/

/

/

Flying restart circuit

/

/

/

/

2 parameter sets

/

/

/

/

Elapsed time meter

/

/

/

/

Assembly with thermal separation of the power stage

as from

8215E

/

/

Temperature-dependent blower activation

/

/

PTC monitoring of the motor by integrated evaluation

option

option

/

/

Process and speed controller

/*

/*

/*

Setpoint summation

/*

/*

/*

Level inversion for digital inputs

/*

/*

/*

Priority for digital inputs

/*

/*

/*

Manual/remote changeover (H/Re)

/*

/*

/*

Belt monitoring

/*

/*

/*

Selection of an inverse analog setpoint

/*

/*

/*

Limit frequencies

/*

/*

/*

Ramp function generator S-shape

/*

/*

/*

Motor phase failure detection

/*

/*

Show/Hide Bookmarks