3 dancer-position control (line drive), Dancer-position control (line drive), Commissioning – Lenze 8200 Frequency inverters User Manual
Page 128: Show/hide bookmarks
Advertising
Commissioning
8200SHB0199
5-23
5.5.3
Dancer-position control (line drive)
M
3~
Main setpoint ~
0 ... 10 V, 0/4 ... 20 mA
W
E
A
F
G
5V
R1 Dancer potentiometer
1 ... 10 kOhm
V
V
V
1
2
1
S
R1
V
U
Z1
K1
F1
Z2
L1 L2 L3
7
9
8
8279
X1
RUN
PRG
STP
SH
L
W
V
U
G
-U
G
+U
L1
L2
L3
Ctrl.
enable
JOG1
QSP
INFL_0
28
E1
E3
E2
E4
39
20
PE
FIG 5-4
Application of a dancer-position control
Z1
Mains filter required for radio interference level A or B. For mains chokes see chapter 3.4 ff.
Z2
Motor filter/sine filter required for long motor cables or motors not designed for inverter operation
(see chapter 4.2.7.2).
Shield all signal and motor cables. Please observe the corresponding installation instructions given in chapters 4.2
and 4.3.
Show/Hide Bookmarks