background image

Configuration

8200SHB0199

7-80

Code

IMPORTANT

Possible settings

Name

Code

IMPORTANT

Info

Choice

Lenze

Name

C036 Voltage/current for

DCB

*

0.00

{0.02 %}

40.00 Page 7-56

*depends on the unit

C037

œ JOG value 1

20.00

0.00

{0.02 Hz}

480.00 Page 7-43

C038

œ JOG value 2

30.00

0.00

{0.02 Hz}

480.00 Page 7-43

C039

œ JOG value 3

40.00

0.00

{0.02 Hz}

480.00 Page 7-43

C050*

œ Output frequency

Page 7-62

Display only

C052* Motor voltage

Page 7-62

Display only [V]

C054* Motor current

Page 7-62

Display only [A]

C056* Unit load

Page 7-62

Display only [%]

C061* Heat sink

temperature

Page 7-62

Display only [°C]

C079 Oscillation damping

*

Page 7-31

* depends on the unit
Is not transferred when
transferring

822X/824X

5

0

{1}

80

transferring
parameters via the
operating module.

C088 Rated motor current

821X/822X/824X

*

0.0 ... 1.2

k rated output current

Page 7-27

* depends on the unit

C091 Motor cos

j

821X/822X/824X

*

0.4

{0.1}

1.0

Page 7-27

* depends on the unit

C093* Type

Page 7-64

C093*

820X

820X

821X

821X

822X/824X

822X

C099* Software version

Page 7-64

Display only

C099*

820X

82 1x

(Software 1x)

Display only

821X

82 2x

(Software 2x)

82 1x

(Software 1x)

822X/824X

82 1x

(Software 1x)

C105 Deceleration time

QSP

821X/822X/824X

5.00

0.00

{0.02 s}

999.00

Page 7-55

C106 Holding time for

autom. DC injection
brake

Page 7-56

820X

0.00

0.00

{0.01 s}

50.00

821X/822X

824X

0.02

0.00

{0.01 s}

999.00

C108* Gain (C111)

Page 7-69

C108*

820X

220

0

{1}

255

821X/822X/

824X

128

0

{1}

255

C111

¤ Monitor signal

-0-

-0-

Field frequency

-1-

Unit load

-2-

Motor current

-3-

DC-bus voltage

Page 7-69

Show/Hide Bookmarks

Advertising