Installation – Lenze 8200 Frequency inverters User Manual

Page 89

Advertising
background image

Installation

8200SHB0199

4-32

-

The motor cable should be as short as possible because of the positive
effect on the drive characteristic.

- FIG 4-19 shows the relation between the motor cable length and the

possibly required output filters.

- For group drives (several motors connected to one controller) it is

necessary to calculate the resulting cable length I

res

:

,

UHV

VXP RI DOO PRWRU FDEOH OHQJWKV ô 1R RI PRWRU FDEOHV

¯

- The components stated in FIG 4-19 are valid for chopper frequencies

$

8 kHz (C018 = -0-, -1-). When using controllers with chopper

frequencies > 8 kHz, different measures may be required. Please contact
Lenze.

- When using unscreened motor cables, the data indicated in FIG 4-19 are

valid for the double motor cable length.

- Please contact Lenze when the absolute or resulting motor cable lengths

are > 200 m.

Type

Permissible control mode C014

8201
8202

-0-, -1-,

-2-, -3-

-2-, -3-

-2-, -3-

+ motor filter/

-2-, -3-

+ sine filter

8203

-0-, -1-,

-2-, -3-

-2-, -3-

-2-, -3-

+ motor filter/

-2-, -3-

+ sine filter

8204

-2-, -3-

+ motor filter/

+ sine filter

0

15

25

50

100

200

Motor cable length (resulting), screened in m

Type

Permissible control mode C014

8211

-2-,
-3-,

-4-

-2-, -3-

-2-, -3-

-2-, -3-

8212

-2-, -3-, -4-

-2-, -3-

-2-, -3-

+ motor filter/

-2-, -3-

+ sine filter

8213/8214

+ motor filter/

motor choke

+ sine filter

8213/8214

motor choke

+ sine filter

8213/8214
8215/8216

-2-, -3-, -4-

motor choke

8215/8216

-2-, -3-, -4-

8215/8216
8217/8218

-2-, -3-, -4-

8217/8218

0

15 25

50

100

200

Motor cable length (resulting), screened in m

Type

Additionally required output filters in the motor cable

8221/8222

motor filter/motor choke

motor choke

8223/8224/8225
8226/8227

none

none

motor choke

(contact Lenze)

8241/8242/8243
8244/8245/8246

none

motor filter/motor choke

sine filter

0

50

100

200

Motor-cable length (resulting), screened in m

FIG 4-19

Output filters additionally required in the motor cable