2 process and speed controller for c005 = -1, Process and speed controller for c005 = -1, Signal flow charts – Lenze 8200 Frequency inverters User Manual

Page 299: Show/hide bookmarks

Advertising
background image

Signal flow charts

8200SHB0199

16-8

16.3.2

Process and speed controller for C005 = -1- ... -7-

K35.0134

X1

1

1

8

7

A

D

+

+

C

026

C

027

C

034

S1

/4

250R

+

+

C

427

C

426

O

ffs

et

Ga

in

,

in

ve

rs

e

se

tp

oi

nt

C

urre

nt

m

as

te

r

va

lu

e

0 ... 2

0 m

A

/

4 ... 2

0 m

A

Of

fs

et

Ga

in

E1

C

425

No

rm

al

is

at

io

n

fre

que

nc

y i

np

ut

VC

O

Ex

0 .

..

10 k

H

z

C

010

C0

46

C

005

C

005

C

037

C

038

C

039

3 J

O

G

se

tp

oi

nt

s

C

onf

ig

ur

at

io

n

f

dm

ax

f

dm

ax

0

0

f

dm

in

-2

-,

-3

-,

-5

-,

-7

-

K

ey

pa

d,

L

EC

O

M

, m

oto

r p

ote

nt

io

m

ete

r

Sp

ee

d l

im

ita

tio

n

w

ith

to

rq

ue

c

on

tro

l

C

005 =

5

LE

C

O

M

-6

-

-1

-

f

dm

ax

JO

G

s

et

po

in

ts

-1

- .

..

-3

-

En

ab

le

JO

G

se

tp

oi

nt

E1

E2

E3

E4

D

ire

ct

io

n o

f ro

ta

tio

n

E1

E2

E3

E4

LE

C

O

M

Fr

ee d

ig

ita

l

in

pu

ts

D

ig

ita

l i

np

uts

-0

-

1

-1

-

-1

C

005

C

005

C0

22

C0

47

C

onf

ig

ur

at

io

n

C

onf

ig

ur

at

io

n

C

onf

ig

ur

at

io

n

-1

-

-2

-

-3

-,

-6

-,

-7

-

0

-1

-,

-2

-,

-6

-,

-7

-

-3

-,

-4

-,

-5

-

-1

-,

-2

-,

-3

-,

-4

-,

-5

-

0

-7

-

-6

-

C

049

1.

5 *

IN

un

it

1.

0 *

f

dm

ax

-1

.0

* f

dm

ax

1.

5 *

f

dm

ax

Ke

yp

ad

, L

EC

O

M

,

m

oto

r p

ote

nt

io

m

ete

r

C

051

0

C

00

5 =

-3

- I

m

ax

-

in

di

re

ct

to

rq

ue

li

m

ita

tio

n

C

00

5 =

-4

- a

nd

-5

-

To

rq

ue

s

et

poi

nt

w

ith

to

rq

ue

c

ont

ro

l (

C

014 =

-

4-

)

D

isp

la

y

ac

t. v

al

ue

C

181

C1

81

=0

C1

81

0

+

-

In

flue

nc

e 0

PI

D

co

nt

ro

lle

r

1

-1

E1

E2

E3

E4

Fr

ee d

ig

ita

l

in

pu

ts

C0

70

C

071

C0

72

V

P

K

d

T

N

C0

08

C0

17

1

0

-7

-

R

es

et

I co

m

po

nen

t

C

074

E1

E2

E3

E4

Fr

ee d

ig

ita

l

in

pu

ts

C

238

-0

-

0

-1

-

Ke

yp

ad

, L

EC

O

M

+

+

Fr

eq

ue

nc

y

pr

ec

on

tro

l

C

239

C

005

-1

-

0

-0

-

Ou

tp

ut

fre

que

nc

y

Q M

in

C

onf

ig

ur

at

io

n

f

dm

ax

-f

dm

ax

C0

12

C1

05

C0

13

C1

82

R

FG

-S-

SH

A

PE

Au

to

D

S

B

Ti

S

-s

ha

pe

C6

25

to

C6

28

Sk

ip

fr

eq

ue

nc

ie

s

R

am

p f

un

ct

ion

ge

ne

ra

to

r

Pl

ug

-in

mo

du

le

-0

-

An

al

og

s

et

po

in

t

un

ip

ol

ar

(f

dm

in

... f

dm

ax

)

PI

D

co

nt

ro

ller

ou

tp

ut

In

flu

en

ce

PI

D

co

nt

ro

ller

Q M

IN

Q M

IN

-t

hr

es

ho

ld

1

1
0

0

0 .

..

10 V

-4

-

0

f

dm

ax

-f

dm

ax

7

Re

se

t

Co

nt

ro

l

inhi

bi

t,

DC

B

St

op

LU

, O

U

+

C

ont

ro

l i

nhi

bi

t,

DC

B

,L

U

,O

U

Re

se

t

St

op

Im

ax

, A

ut

o D

C

B

-1

-.

...

-5

-

-6

-,

-7

-

FIG 16-9

Process and speed controller for C005 = -1- ... -7-

Show/Hide Bookmarks

Advertising