Installation

8200SHB0199

4-14

4.1.5

Assembly of the variant 82XX-V003 ”cold plate”

4.1.5.1

General

Fields of application

-

Application of coolers without separately driven fan:

- If e.g. the cooling air is so contaminated that it is not possible to use

separately driven fans. The performance as well as the service life of the
fan would be reduced.

-

High enclosure with thermal separation:

- If thermal separation is required because of the heat generation in the

control cabinet and if the enclosure class of the cooling unit must be
higher than IP41.

-

Application of controllers directly in the machine with reduced assembly
depth:

- Machine components adopt the cooling function.

-

The drive concept provides common cooling units (water cooler, forced-air
cooler, etc.) for all controllers.

-

Because of technical reasons, the convection cooling is not suitable for
continuous powers > 22 kW. Here, forced cooling (e.g. water cooling) is
required.