5 rated data (operation with 120 %overload), 1 operating conditions, 2 types 821x – Lenze 8200 Frequency inverters User Manual

Page 50: Rated data (operation with 120 % overload), Operating conditions, Types 821x, Technical data, 5 rated data

Advertising
background image

Technical Data

8200SHB0199

3-18

3.5

Rated data

(Operation with 120 % overload)

3.5.1

Operating conditions

-

Applications:

- Pumps with square characteristic

- Fans

-

Operation only

- with mains filter or mains choke,

- with mains voltage 3 AC / 400 V / 50 Hz/60 Hz,

- 821X with chopper frequencies

{

8 kHz,

- 822X/824X with chopper frequencies = 4 kHz (chopper

frequencies

{

16 kHz possible, load-dependent derating).

-

Automatic chopper-frequency reduction to 4 kHz.

-

Adapt mains-side accessories to the increased mains current:

- Fuses and cable cross-sections, see chapter 3.6.3.

- For data of other components, see ”Accessories”.

3.5.2

Types 821X

120 % overload

Type

8211

8212

8213

8214

8215

8216

8217

8218

Rated mains current
with mains filter/mains choke

I

r

[A]

3.0

3.9

7.0

7.0

12.0

12.0

20.5

20.5

Data for mains operation with 3 AC / 400 V / 50 Hz/60 Hz ; 450 V

$ V

DC

$ 650 V

Motor power (4 pole ASM)

P

r

[kW]

1.1

1.5

3.0

3.0

5.5

5.5

11.0

11.0

Motor power (4 pole ASM)

P

r

[hp]

1.5

2.0

4.0

4.0

7.5

7.5

15.0

15.0

Output power U, V, W

S

r

[kVA]

2.1

2.7

5.2

5.2

9.0

9.0

16.3

16.3

Output
current

4 kHz

I

r

[A]

3.0

3.9

7.3

7.3

13.0

13.0

23.5

23.5

Output
current

8 kHz

*1)

I

r

[A]

3.0

3.9

7.3

7.3

13.0

13.0

23.5

23.5

Max.
output
current

4 kHz

I

Nm

[A]

3.6

5.9

8.3

11.0

14.1

19.5

24.8

35.3

output
current
for 60 s

2)

8 kHz

*1)

I

Nm

[A]

3.6

5.9

8.3

11.0

14.1

19.5

24.8

35.3

Power loss

P

loss

[W]

65

75

100

100

200

200

400

400

1)

Only with variant “HVAC”

*

No dyn. chopper frequency derating of the inverter

All other data, see chapter 3.4.2 and chapter 3.4.3.

Show/Hide Bookmarks

Advertising