Configuration – Lenze 8200 Frequency inverters User Manual
Page 232
Advertising
![background image](/manuals/566230/232/background.png)
Configuration
8200SHB0199
7-95
Code
IMPORTANT
Possible settings
Name
Code
IMPORTANT
Info
Choice
Lenze
Name
C599*
¤ Current limit value
Motor phase failure
detection
Page 7-73
822X/824X
5
1
{1 %}
50
C625*
Skip frequency 1
480.00 0.00
{0.02 Hz}
480.00 Page 7-33
C626*
Skip frequency 2
480.00 0.00
{0.02 Hz}
480.00 Page 7-33
C627*
Skip frequency 3
480.00 0.00
{0.02 Hz}
480.00 Page 7-33
C628* Bandwidth of skip
frequencies
0.00
0.00
{0.01 %}
100.00 Page 7-33
C988* DC-bus voltage
threshold for DC-bus
voltage control
0
0
{1 %}
200 Page 7-12
-
C988 = 0 %
- No parameter set
changeover via
DC-bus voltage
-
C988 = 1 ... 200 %
- Parameter set
changeover via
DC-bus voltage is
active
Parameter set
changeover via
terminal or LECOM
is not possible with
C988 > 0!