Network of several drives

8200SHB0199

10-15

10.4.2

Central supply via 934X for 821X/822X/824X/93XX

L1

L2

L3

F1...F3

934X

PE

+UG

-UG

Z1

K1

U

V

W

M

3~

PE

L1

L2

L3

PE

+UG

-UG

PE

U

V

W

M

3~

PE

L1

L2

L3

PE

+UG

-UG

PE

F4 F5

Z2

M

3~

L3

N

PE

L1
L2

K1

K1

Mot1

ϑ

ON

OFF

Mot2

ϑ

Mot1

Mot2

821X/ 822X

824X/ 93XX

821X/ 822X

824X/ 93XX

FIG 10-3

Principle diagram: Central supply for network operation of 821X/822X/824X/93XX
Z1

Mains filter/choke

Z2

Regenerative power supply

F1 ... F5

Fuses

K1

Main contactor

Stop!

The DC-bus voltage thresholds of the 93XX controller and the 934X supply unit
must be set to the same value.

Note!

Z2 is selected after balancing the power in the DC-bus. If the power supply of the
supply is not sufficient, a parallel supply can be installed via the mains input of a
controller (see Network of severval drives with decentral supply).