Fault reset methods, Reset the fault, 8 diagnosing and resetting faults – Yaskawa AC Drive P1000 Bypass Technical Manual User Manual

Page 203: Digital operator jvop-183

Advertising
background image

u

Fault Reset Methods

When a fault occurs, the cause of the fault must be removed and the drive must be restarted. The table below lists the different

ways to restart the drive.

After the Fault Occurs

Procedure

Fix the cause of the fault, restart the drive, and

reset the fault

Press

on the HOA keypad.

F2

F1

ESC

M

M

AUTO

OFF

ENTER

RESET

-DRIVE-

U1- 01=60.00Hz

----------------

U1- 02=60.00Hz

JOG FWD FWD/REV

-Rdy-

ALM

DIGITAL OPERATOR JVOP-183

HAND

Freq Ref (OPR)

Resetting via Fault Reset Digital Input DI-oo

Resetting via Fault Reset serial command.

Close then open the fault signal digital input via the

digital input defined as Fault Reset (one of Z2-01

through Z2-08 set to 34).

Fault Reset Switch

Drive

DI- Fault Reset Digital Input

IG24 24V Common Digital Input Common

Turn off the main power supply if the above methods do not reset the fault. Reapply power after the

HOA keypad display has turned off.

When an “SC” error occurs, contact Yaskawa or a Yaskawa agent before cycling the power to the drive.

ON

OFF

2

1

Note:

If the Run command is present, the drive will disregard any attempts to reset the fault. Remove the Run command before attempting to clear

a fault situation.

6.8 Diagnosing and Resetting Faults

YASKAWA SIEP YAIP1B 01A YASKAWA AC Drive – P1000 Bypass Technical Manual

203

6

Diagnostics & Troubleshooting

Advertising