Yaskawa AC Drive P1000 Bypass Technical Manual User Manual

Page 376

Advertising
background image

No.

Name

User

Setting

E1-05

Maximum Voltage

E2-01

Motor Rated Current

E2-03

Motor No-Load Current

H1-03

Multi-Function Digital Input Terminal S3 Function

Selection

H1-04

Multi-Function Digital Input Terminal S4 Function

Selection

H1-05

Multi-Function Digital Input Terminal S5 Function

Selection

H1-06

Multi-Function Digital Input Terminal S6 Function

Selection

H1-07

Multi-Function Digital Input Terminal S7 Function

Selection

H3-01

Terminal A1 Signal Level Selection

H3-02

Terminal A1 Function Selection

H3-03

Terminal A1 Gain Setting

H3-04

Terminal A1 Bias Setting

H3-05

Terminal A3 Signal Level Selection

H3-06

Terminal A3 Function Selection

H3-07

Terminal A3 Gain Setting

H3-08

Terminal A3 Bias Setting

H3-09

Terminal A2 Signal Level Selection

H3-10

Terminal A2 Function Selection

H3-11

Terminal A2 Gain Setting

H3-12

Terminal A2 Bias Setting

H3-13

Analog Input Filter Time Constant

H3-14

Analog Input Terminal Enable Selection

H3-16

Terminal A1 Offset

H3-17

Terminal A2 Offset

H3-18

Terminal A3 Offset

H4-01

Multi-Function Analog Output Terminal FM

Monitor Selection

H4-02

Multi-Function Analog Output Terminal FM Gain

H4-03

Multi-Function Analog Output Terminal FM Bias

H4-04

Multi-Function Analog Output Terminal AM

Monitor Selection

L1-01

Motor Overload Protection Selection

L1-02

Motor Overload Protection Time

L2-01

Momentary Power Loss Operation Selection

L2-03

Momentary Power Loss Minimum Baseblock Time

L2-05

Undervoltage Detection Level (Uv1)

L3-02

Stall Prevention Level during Acceleration

L3-03

Stall Prevention Limit during Acceleration

No.

Name

User

Setting

L3-04

Stall Prevention Selection during Deceleration

L3-06

Stall Prevention Level during Run

L3-11

Overvoltage Suppression Function Selection

L3-25

Load Inertia Ratio

L5-01

Number of Auto Restart Attempts

L5-02

Auto Restart Fault Output Operation Selection

L5-03

Time to Continue Making Fault Restarts

L5-04

Fault Reset Interval Time

L5-05

Fault Reset Operation Selection

L6-02

Torque Detection Level 1

L6-03

Torque Detection Time 1

L6-13

Motor Underload Protection Selection

L6-14

Motor Underload Protection Level at Minimum

Frequency

L8-02

Overheat Alarm Level

L8-05

Input Phase Loss Protection Selection

L8-06

Input Phase Loss Detection Level

L8-07

Output Phase Loss Protection

L8-09

Output Ground Fault Detection Selection

L8-38

Carrier Frequency Reduction Selection

n1-01

Hunting Prevention Selection

n1-02

Hunting Prevention Gain Setting

n3-04

High-Slip Braking Overload Time

n3-13

Overexcitation Deceleration Gain

o1-03

Digital Operator Display Selection

o1-09

Frequency Reference Display Units

o1-10

User-Set Display Units Maximum Value

o1-11

User-Set Display Units Decimal Display

o2-04

Drive Model Selection

o4-03

Cooling Fan Maintenance Operation Time Setting

S1-01

Dynamic Audible Noise Control Selection

S1-02

Voltage Reduction Rate

S1-03

Voltage Restoration Level

S1-04

Voltage Restoration Complete Level

S1-05

Voltage Restoration Sensitivity Time Constant

S1-06

Voltage Restoration Time Constant at Impact

S2-01

Sequence Timer 1 Start Time

S2-02

Sequence Timer 1 Stop Time

S2-03

Sequence Timer 1 Day Selection

S2-04

Sequence Timer 1 Selection

S2-05

Sequence Timer 1 Reference Source

S2-06

Sequence Timer 2 Start Time

S2-07

Sequence Timer 2 Day Selection

H.3 User Setting Table

376

YASKAWA SIEP YAIP1B 01A YASKAWA AC Drive – P1000 Bypass Technical Manual