Drive derating data, Rated current depending on carrier frequency, A.4 drive derating data – Yaskawa AC Drive P1000 Bypass Technical Manual User Manual

Page 231

Advertising
background image

A.4 Drive Derating Data

The drive can be operated at above the rated temperature, altitude, and default carrier frequency by derating the drive capacity.

u

Rated Current Depending on Carrier Frequency

The tables below show the drive output current depending on the carrier frequency settings.
The 2 kHz values shown for ND below are equal to the drive rated current shown on the drive nameplate. Increasing the carrier

frequency above 2 kHz will reduce the ND rated output current of the drive.

Table A.10 Three-Phase 208 Vac Bypass Drive Carrier Frequency and Current Derating

Three-Phase 208 Vac Bypass Drives

Drive Model

Rated Current [A]

Normal Duty Rating (ND)

2 kHz

8 kHz

15 kHz

2A0004

3.5

3.2

2.56

2A0006

6

5

4

2A0008

8

6.9

5.5

2A0010

9.6

8

6.4

2A0012

12

11

8.8

2A0018

17.5

14

11.2

2A0021

21

17.5

14

2A0030

30

25

20

2A0040

40

33

26.4

2A0056

56

47

37.6

2A0069

69

60

48

2A0081

81

75

53

2A0110

110

85

60

2A0138

138

115

81

Three-Phase 208 Vac Bypass Drives

Drive Model

Rated Current [A]

Normal Duty Rating (ND)

2 kHz

5 kHz

10 kHz

2A0169

169

145

116

2A0211

211

180

144

2A0250

250

215

172

2A0312

312

283

226

2A0360

360

346

277

2A0415

415

415

332

Table A.11 Three-Phase 480 Vac Bypass Drive Carrier Frequency and Current Derating

Three-Phase 480 Vac Bypass Drives

Drive Model

Rated Current [A]

Normal Duty Rating (ND)

2 kHz

8 kHz

15 kHz

4A0002

2.1

1.8

1.1

4A0004

4.1

3.4

2

4A0005

5.4

4.8

2.9

4A0007

6.9

5.5

3.3

4A0009

8.8

7.2

4.3

4A0011

11.1

9.2

5.5

4A0018

17.5

14.8

8.9

A.4 Drive Derating Data

YASKAWA SIEP YAIP1B 01A YASKAWA AC Drive – P1000 Bypass Technical Manual

231

A

Specifications

Advertising