7 types and roles of monitor data, Melsec-q, 1] monitoring the system – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 100

Advertising
background image

5 - 12

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

5.1.7 Types and roles of monitor data

The monitor data area in the buffer memory stores data relating to the operating state

of the positioning system, which are monitored as required while the positioning

system is operating.

The following data are available for monitoring.

System monitoring:

Monitoring of the QD75 configuration and operation history (through the system

monitor data Md.1 through

Md.19

)

Axis operation monitoring:

Monitoring of the current position and speed, and other data related to the

movements of axes (through the axis monitor data

Md.20

through

Md.48

)

The axis monitor data are refreshed every 1.8 ms. Note that "

Md.21

Machine

feed value", "

Md.22

Feedrate", "

Md.28

Axis feedrate" and "

Md.30

External

input/output signal" are refreshed every 56.8ms. Also, "

Md.23

Valid M code", is

updated when the "M code ON signal [X4, X5, X6, X7]" turns ON.

[1] Monitoring the system

Monitoring the positioning system operation history

Monitoring details

Corresponding item

Whether the system is in the test mode or not

Md.1

In test mode flag

Start information

Md.3

Start information

Start No.

Md.4

Start No.

Hour

Md.5

Start (Hour)

Start

Minute:second

Md.6

Start (Minute:second)

Error upon starting

Md.7

Error judgment

History of data that
started an operation

Latest pointer No.

Md.8

Start history pointer

Axis in which the error occurred

Md.9

Axis in which the error occurred

Axis error No.

Md.10

Axis error No.

Hour

Md.11

Axis error occurrence Hour

Axis error occurrence

Minute:second

Md.12

Axis error occurrence Minute:second

History of all errors

Latest pointer No.

Md.13

Error history pointer

Axis in which the warning occurred

Md.14

Axis in which the warning occurred

Axis warning No.

Md.15

Axis warning No.

Hour

Md.16

Axis warning occurrence (Hour)

Axis warning
occurrence

Minute:second

Md.17

Axis warning occurrence (Minute:second)

History of all warnings

Latest pointer No.

Md.18

Warning history pointer

Number of write accesses
to the flash ROM after the
power is switched ON

Number of write accesses to flash ROM

Md.19

No. of write accesses to flash ROM

Advertising