MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Pr.36 Sudden stop deceleration time

Set the time to reach speed 0 from " Pr.8 Speed limit value" during the sudden

stop.
The illustration below shows the relationships with other parameters.

When positioning is started,
the acceleration starts following
the "acceleration time".

1) Positioning start

2) Sudden stop cause occurrence

When a "sudden stop cause" occurs,
the deceleration starts following the
"sudden stop deceleration time".

3) Positioning stop

When a "sudden stop cause"
does not occur, the decelera-
tion starts toward the stop
position following the "decel-
eration time".

Actual accel-
eration time

Actual sudden stop
deceleration time

Acceleration time

Actual decel-
eration time

Deceleration time

Speed limit
value

Pr.8

Command
speed

Da.8

Pr.36

Sudden stop
deceleration time

Acceleration time 0

Pr.9

Acceleration time 1

Pr.25

Acceleration time 2

Pr.26

Acceleration time 3

Pr.27

Deceleration time 0

Pr.10

Deceleration time 1

Pr.28

Deceleration time 2

Pr.29

Deceleration time 3

Pr.30