Melsec-q, Appendices, 2) function comparisons – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 689

Advertising
background image

Appendix - 47

MELSEC-Q

APPENDICES

Model

Item

QD75P1

QD75D1

QD75P2

QD75D2

QD75P4

QD75D4

A1SD75P1

-S3

A1SD75P2

-S3

A1SD75P3

-S3

STRT signal

(integrated into "CHG")

(External start signal)

CHG signal

External command signal (External start or
speed-position switching selectable with
parameters)

Speed-position switching signal

In-position (INP)

(for monitor)

I/O signal for
external devices

Signal logic switching

Command pulse output signal only

Connection with peripheral
devices

Connection via PLC CPU,
Q Corresponding Serial Communication
Module, Q Corresponding MELSEC/H
Remote I/O Module

Direct connection

AD71TU

AD75TU

A6GPP, A6PHP

Peripheral devices
(data setting, etc.)

DOS/V personal computer

: Possible, : Not possible

1: Up to 100 data items/axis of positioning data (No. 1 to 100) can be set using the buffer memory. The positioning data in the buffer

memory is not backed up.

2: Indicates the standard mode/stepping motor mode about A1SD75P

-S3.

3: Indicates the INC mode/ABS mode in speed-position switching control.

4: The deviation counter clear signal output time can be set with parameters.

5: The near pass function is valid only during the continuous path control. (A1SD75: Selected with parameters, QD75: Standard function)

(2) Function comparisons

Functions added to those of A1SD75P1-S3/A1SD75P2-S3/A1SD75P3-S3

Added functions

Remarks

External I/O signal logic switching function

Refer to Section 13.4.

Inching operation

Refer to Section 11.3.

Target position change function

Refer to Section 12.7.5.

Multiple axes simultaneous start control

Refer to Section 10.5.

Control systems

3-axis linear interpolation control
4-axis linear interpolation control
3-axis fixed-feed control
4-axis fixed-feed control
2-axis speed control
3-axis speed control
4-axis speed control
Position-speed switching control
NOP instruction
LOOP instruction, LEND instruction

Refer to Chapter 9.

Dedicated
instructions

Absolute position restoration
Positioning start
Teaching
Flash ROM writing
Parameter initialization

Refer to Chapter 14.

Automatic refresh of intelligent function modules

Refer to GX Configurator-QP Operating Manual.

Output hold/clear parameter setting during PLC CPU error stop

Refer to QCPU User's Manual

(Function Explanation, Program Fundamentals).

Flash ROM write limit

Refer to Section 13.3.

Speed-position switching control (ABS mode)

Refer to Section 9.2.7.

Pre-reading start function

Refer to Section 12.7.8.

External I/O signal monitor function

Refer to Section 13.5.

Multiple PLC compatible function

Refer to QCPU User's Manual (Multiple CPU System).

Deceleration start flag function

Refer to Section 12.7.9

Stop command processing for deceleration stop function

Refer to Section 12.7.10